# Electrical permit ELE2025-01336 at 2722 Winding Trail Pl, Boulder

Boulder Planning and Development Services permit ELE2025-01336: issued Jan 13, 2026 for electrical work at 2722 Winding Trail Pl. 200A main service upgrade ? Remove the existing main breaker panel and replace it with a new exterior-rated 200A, 8-space/16-circuit panel equipped with feed-through lugs for subpanel distribution. ? Install a new 200A lever-bypass meter housing per Xcel Energy requirements. ? Cut back the existing service lateral conduit where it enters the meter housing and install a slip sleeve. ? Install a new 2-inch PVC riser on the exterior wall to route new subpanel feeders into the basement drop ceiling. ? Reinstall the whole-home surge protector onto the new exterior panel to maintain NEC compliance and system protection. 200A basement subpanel upgrade ? Remove and replace the existing basement subpanel with a new 200A main-lug-only interior panel with 42 spaces to accommodate existing loads and allow for future expansion. ? Provide and install AFCI-protected breakers for required circuits per NEC article 210.12. ? Organize, tidy, and properly terminate all existing branch circuit conductors into the new panel. ? Fully label all breakers and branch circuits for homeowner clarity and future maintenance. New 200a feeder installation (approx. 35 ft) ? Install new 200A-rated feeder conductors from the exterior panel to the basement subpanel. ? Route feeders through the newly installed PVC riser into the basement drop ceiling. ? Secure wiring to framing as required and ensure all penetrations meet fire-blocking requirements. EV Charger circuit installation ? Install a new dedicated 50A or 60A EV charging circuit, depending on the charger type the homeowner provides. ? Circuit may terminate in either: ? A NEMA receptacle (e.g., 14-50), or ? A hardwired EV charger, depending on manufacturer requirements. ? Route wiring from the basement subpanel to the garage in a clean, code-compliant manner using EMT, MC, or PVC conduit as needed. Grounding & bonding system upgrade ? Install two new 8 ft copper ground rods, bonded together and tied to the service equipment. ? Install a new #4 bare copper water bond to the incoming water service within 5 ft of entry. ? Install a new intersystem bonding bridge for low-voltage grounding compatibility.

- Permit number: ELE2025-01336
- Issued: Jan 13, 2026
- Type of work: Electrical (city: Electrical Permit, Electrical Permit)
- Status: Finished (city: Letter of Completion)
- Reported cost: $4,461
- ZIP code: 80304
- All permits at this address: https://nearbypermits.com/boulder/address/2722-winding-trail-pl/

---
Source: Boulder Planning and Development Services permit data (https://www.arcgis.com/home/item.html?id=e3ff6248e4a547bcba31025d2c5c9fee). Checked 2026-10-11 10:05 UTC. Nearby Permits, https://nearbypermits.com. JSON API and MCP server: https://nearbypermits.com/developers/

Every permit at 2722 Winding Trail Pl: https://nearbypermits.com/boulder/address/2722-winding-trail-pl/