# Electrical permit ELE2026-00960 at 4198 Nevis St, Boulder

Boulder Planning and Development Services permit ELE2026-00960: issued Sep 4, 2026 for electrical work at 4198 Nevis St. New 200A Service Installation Panel Installation: Install one (1) new Leviton 150-200-Amp Load Center with a main service disconnect. Ensure the panel is plumb, level, and securely fastened. https://leviton.com/products/residential/load-centers Service Conductor Installation: Connect service entrance conductors from the utility connection point to the line side of the new meter socket. Grounding Electrode System (GES): Install new GES that meets or exceeds NEC Article 250 requirements as needed. Drive new 8-foot copper-clad ground rods, spaced a minimum of 6 feet apart as needed. Install a continuous #4 AWG bare copper Grounding Electrode Conductor (GEC) from the panel's neutral/ground bus to both ground rods using approved acorn clamps as needed. Install a new Intersystem Bonding Bridge and connect it to the GEC for the bonding of telephone, cable, and satellite systems as needed. Whole-Home Surge Protection: Install one (1) new Leviton Type 1 or Type 2 Whole-Home Surge Protective Device (SPD) inside the load center. Connect the SPD to a dedicated 2-pole circuit breaker, positioned as close to the main breaker as physically possible to ensure maximum effectiveness, per manufacturer and NEC best practices. Circuit Reconnection & Breaker Installation Circuit Re-routing: Extend existing branch circuit wiring as necessary to neatly enter the new load center. All connections will be made within approved junction boxes if required. Breaker Installation: Install new Leviton circuit breakers for all branch circuits, sized appropriately for the connected wire gauge. Breakers shall include modern safety features as required by the current NEC: Dual-Function AFCI/GFCI Breakers: For all circuits requiring both Arc-Fault and Ground-Fault protection, including kitchens, bathrooms, laundry rooms, garages, and outdoor outlets. Arc-Fault (AFCI) Breakers: For all circuits requiring Arc-Fault protection, including bedrooms, living rooms, hallways, dining rooms, and other general living spaces. Standard Breakers: For circuits that do not require AFCI/GFCI protection, such as a dedicated furnace or fire alarm circuit. Electrical Wiring.

- Permit number: ELE2026-00960
- Issued: Sep 4, 2026
- Type of work: Electrical (city: Electrical Permit, Electrical Permit)
- Status: Issued (city: Issued)
- Reported cost: $12,000
- ZIP code: 80301
- All permits at this address: https://nearbypermits.com/boulder/address/4198-nevis-st/

---
Source: Boulder Planning and Development Services permit data (https://www.arcgis.com/home/item.html?id=e3ff6248e4a547bcba31025d2c5c9fee). Checked 2026-10-08 01:39 UTC. Nearby Permits, https://nearbypermits.com. JSON API and MCP server: https://nearbypermits.com/developers/

Every permit at 4198 Nevis St: https://nearbypermits.com/boulder/address/4198-nevis-st/