# Mechanical (HVAC) permit MEC2025-01359 at 2299 4th St, Boulder

Boulder Planning and Development Services permit MEC2025-01359: issued Aug 20, 2025 for mechanical (hvac) work at 2299 4th St. Scope of Work: Supply and Install Floor Mounted Triangle Tube Instinct 199 Model No: 199 INSFS199S 199,000 BTUs Install flue by connecting to existing boiler flue. Install new fittings, valves, and piping to tie on to existing boiler system. Install low voltage wiring Install new condensate neutralizer Connect new boiler to existing heat supply and return piping/manifolds All new plastic glued vents for fuel burning appliances must undergo pressure testing. To facilitate the inspection process, please provide photographic evidence of the pressure test directly to the assigned inspector on the day the rough mechanical inspection is scheduled. Approved tests: 10 ft water test, 5 PSI positive pressure, or Negative 5 psi air pressure test for 15 Minutes.

- Permit number: MEC2025-01359
- Issued: Aug 20, 2025
- Type of work: Mechanical (HVAC) (city: Mechanical Permit, Mechanical HVAC/Solar)
- Status: Finished (city: Letter of Completion)
- Reported cost: $19,486
- ZIP code: 80302
- All permits at this address: https://nearbypermits.com/boulder/address/2299-4th-st/

---
Source: Boulder Planning and Development Services permit data (https://www.arcgis.com/home/item.html?id=e3ff6248e4a547bcba31025d2c5c9fee). Checked 2026-10-06 13:28 UTC. Nearby Permits, https://nearbypermits.com. JSON API and MCP server: https://nearbypermits.com/developers/