# Mechanical (HVAC) permit MEC2025-01458 at 2672 Winding Trail Dr, Boulder

Boulder Planning and Development Services permit MEC2025-01458: issued Sep 12, 2025 for mechanical (hvac) work at 2672 Winding Trail Dr. Void-180 days no activity mitsubishi hyper heat 3 zone mini split system w/ infrastructure for two additional units 9/12/25 - revision to remove electrical scope. Will be using existing electrical. All new plastic glued vents for fuel burning appliances must undergo pressure testing. To facilitate the inspection process, please provide photographic evidence of the pressure test directly to the assigned inspector on the day the rough mechanical inspection is scheduled. Approved tests: 10 ft water test, 5 PSI positive pressure, or Negative 5 psi air pressure test for 15 Minutes.