# Mechanical (HVAC) permit MEC2025-01749 at 4595 Whitney Pl, Boulder

Boulder Planning and Development Services permit MEC2025-01749: issued Oct 17, 2025 for mechanical (hvac) work at 4595 Whitney Pl. Installation of a 3 Ton Mitsubishi Ductless Cold Climate Heat Pump System. Condenser and four indoor wall-mounted units and one 5-port branch box. Electrical Scope is as follows: add one 45A Breaker with circuit, and new GFCI Service Outlet. All new plastic glued vents for fuel burning appliances must undergo pressure testing. To facilitate the inspection process, please provide photographic evidence of the pressure test directly to the assigned inspector on the day the rough mechanical inspection is scheduled. Approved tests: 10 ft water test, 5 PSI positive pressure, or Negative 5 psi air pressure test for 15 Minutes.

- Permit number: MEC2025-01749
- Issued: Oct 17, 2025
- Type of work: Mechanical (HVAC) (city: Mechanical Permit, Mechanical with Electrical)
- Status: Finished (city: Letter of Completion)
- Reported cost: $26,574
- ZIP code: 80305
- All permits at this address: https://nearbypermits.com/boulder/address/4595-whitney-pl/

---
Source: Boulder Planning and Development Services permit data (https://www.arcgis.com/home/item.html?id=e3ff6248e4a547bcba31025d2c5c9fee). Checked 2026-10-08 06:39 UTC. Nearby Permits, https://nearbypermits.com. JSON API and MCP server: https://nearbypermits.com/developers/

Every permit at 4595 Whitney Pl: https://nearbypermits.com/boulder/address/4595-whitney-pl/