# Mechanical (HVAC) permit MEC2025-01751 at 260 Spruce St, Boulder

Boulder Planning and Development Services permit MEC2025-01751: issued Oct 17, 2025 for mechanical (hvac) work at 260 Spruce St. install/ replace 4 zone 36k btu Lennox Cold Climate Mini Split system into the two 2nd level bedrooms and 3rd level loft and 1 in the main floor living room All new plastic glued vents for fuel burning appliances must undergo pressure testing. To facilitate the inspection process, please provide photographic evidence of the pressure test directly to the assigned inspector on the day the rough mechanical inspection is scheduled. Approved tests: 10 ft water test, 5 PSI positive pressure, or Negative 5 psi air pressure test for 15 Minutes.

- Permit number: MEC2025-01751
- Issued: Oct 17, 2025
- Type of work: Mechanical (HVAC) (city: Mechanical Permit, Mechanical with Electrical)
- Status: Finished (city: Letter of Completion)
- Reported cost: $23,168
- ZIP code: 80302
- All permits at this address: https://nearbypermits.com/boulder/address/260-spruce-st/

---
Source: Boulder Planning and Development Services permit data (https://www.arcgis.com/home/item.html?id=e3ff6248e4a547bcba31025d2c5c9fee). Checked 2026-10-08 09:56 UTC. Nearby Permits, https://nearbypermits.com. JSON API and MCP server: https://nearbypermits.com/developers/

Every permit at 260 Spruce St: https://nearbypermits.com/boulder/address/260-spruce-st/