# Mechanical (HVAC) permit MEC2025-01894 at 540 Ithaca Dr, Boulder

Boulder Planning and Development Services permit MEC2025-01894: issued Nov 4, 2025 for mechanical (hvac) work at 540 Ithaca Dr. Replace furnace & AC - new 80K BTU 97% furnace + 3 Ton 16 SEER2 Heat Pump [heat pump same loc as prev condenser in exterior of home] PLEASE NOTE: APPLICABLE ONLY TO SYSTEMS WITH FUEL BURNING APPLIANCES: All new plastic glued vents for fuel burning appliances must undergo pressure testing. To facilitate the inspection process, please provide photographic evidence of the pressure test directly to the assigned inspector on the day the rough mechanical inspection is scheduled. Approved tests: 10 ft water test, 5 PSI positive pressure, or Negative 5 psi air pressure test for 15 Minutes.

- Permit number: MEC2025-01894
- Issued: Nov 4, 2025
- Type of work: Mechanical (HVAC) (city: Mechanical Permit, Mechanical with Electrical)
- Status: Finished (city: Letter of Completion)
- Reported cost: $18,696
- ZIP code: 80305
- All permits at this address: https://nearbypermits.com/boulder/address/540-ithaca-dr/

---