# Mechanical (HVAC) permit MEC2026-00136 at 2247 Walnut St, Boulder

Boulder Planning and Development Services permit MEC2026-00136: issued Jan 28, 2026 for mechanical (hvac) work at 2247 Walnut St. Voided for inactivity - no inspection within 180 days Replace furnace - new 60K BTU 80% furnace PLEASE NOTE: APPLICABLE ONLY TO SYSTEMS WITH FUEL BURNING APPLIANCES: All new plastic glued vents for fuel burning appliances must undergo pressure testing. To facilitate the inspection process, please provide photographic evidence of the pressure test directly to the assigned inspector on the day the rough mechanical inspection is scheduled. Approved tests: 10 ft water test, 5 PSI positive pressure, or Negative 5 psi air pressure test for 15 Minutes.

- Permit number: MEC2026-00136
- Issued: Jan 28, 2026
- Type of work: Mechanical (HVAC) (city: Mechanical Permit, Mechanical with Electrical)
- Status: Cancelled (city: Void)
- Reported cost: $5,150
- ZIP code: 80302
- All permits at this address: https://nearbypermits.com/boulder/address/2247-walnut-st/

---
Source: Boulder Planning and Development Services permit data (https://www.arcgis.com/home/item.html?id=e3ff6248e4a547bcba31025d2c5c9fee). Checked 2026-10-06 18:02 UTC. Nearby Permits, https://nearbypermits.com. JSON API and MCP server: https://nearbypermits.com/developers/

Every permit at 2247 Walnut St: https://nearbypermits.com/boulder/address/2247-walnut-st/