# Mechanical (HVAC) permit MEC2026-00157 at 935 Waite Dr, Boulder

Boulder Planning and Development Services permit MEC2026-00157: issued Feb 4, 2026 for mechanical (hvac) work at 935 Waite Dr. Installation of 3 Ton Mitsubishi Ducted Heat Pump System. Condenser Model# SUZ-AK36NLHZ, AHU Model# SVZ-AP36NL. Electrical Scope of work is as follows: add new 120v GFCI Circuit, 30A Breaker with Circuit to service HP, 30A Breaker with Circuit and 120v GFCI Circuit to service future replacement HPWH PLEASE NOTE: APPLICABLE ONLY TO SYSTEMS WITH FUEL BURNING APPLIANCES: All new plastic glued vents for fuel burning appliances must undergo pressure testing. To facilitate the inspection process, please provide photographic evidence of the pressure test directly to the assigned inspector on the day the rough mechanical inspection is scheduled. Approved tests: 10 ft water test, 5 PSI positive pressure, or Negative 5 psi air pressure test for 15 Minutes.