# Mechanical (HVAC) permit MEC2026-01654 at 5375 Kewanee Dr, Boulder

Boulder Planning and Development Services permit MEC2026-01654: issued Sep 10, 2026 for mechanical (hvac) work at 5375 Kewanee Dr. New 2 zone mini split heat pump HYPER-MXZ-3D30NLHZ Mitsubishi Hyper Heat MXZ-3D 30,000 BTU Outdoor Unit Heat Pump (combine w/up to 3 heads). R454B Up to 20.00 SEER2 & 10.00HSPF2 PLEASE NOTE: APPLICABLE ONLY TO SYSTEMS WITH FUEL BURNING APPLIANCES: All new plastic glued vents for fuel burning appliances must undergo pressure testing. To facilitate the inspection process, please provide photographic evidence of the pressure test directly to the assigned inspector on the day the rough mechanical inspection is scheduled. Approved tests: 10 ft water test, 5 PSI positive pressure, or Negative 5 psi air pressure test for 15 Minutes. Any electrical work required beyond a like-for-like replacement of equipment will require an electrical permit for inspection of the electrical scope.

- Permit number: MEC2026-01654
- Issued: Sep 10, 2026
- Type of work: Mechanical (HVAC) (city: Mechanical Permit, Mechanical HVAC/Solar)
- Status: Issued (city: Issued)
- Reported cost: $11,000
- ZIP code: 80303
- All permits at this address: https://nearbypermits.com/boulder/address/5375-kewanee-dr/

---
Source: Boulder Planning and Development Services permit data (https://www.arcgis.com/home/item.html?id=e3ff6248e4a547bcba31025d2c5c9fee). Checked 2026-10-07 07:40 UTC. Nearby Permits, https://nearbypermits.com. JSON API and MCP server: https://nearbypermits.com/developers/