# Building permits at 160 N Wacker Dr, Chicago, IL

Eight permits on record here. The newest, Apr 1: Fire alarm: repair existing system. Within a quarter mile, the city has issued 305 more permits since May 1.

## At this address

| Date | Type | Work | Cost | Permit |
|---|---|---|---|---|
| Apr 1, 2026 | Fire systems | Fire alarm: repair existing system. Affects: 0 dwelling units; 0 non-residential units. High-rise building: no. Voice communication: no. Special locking: no. Monitoring type: supervising station. Specific location: 1 - 4th floors. | Not listed | [B200462788](https://nearbypermits.com/chicago/permit/B200462788/) |
| Jan 12, 2026 | Alteration or repair | Self-cert 2019 CBRC: interior alterations to existing 6 story office building. Scope includes floors 1, 2, 3 and 4. Work to include new partitions, mechanical, electrical, plumbing and finishes as per plans. Demo pulled under permit #101073944. B - Business. 1A construction | $1,500,000 | [101071032](https://nearbypermits.com/chicago/permit/101071032/) |
| Sep 11, 2025 | Alteration or repair | Self-cert 2019 CBRC: interior demo only to existing 6 story office building. Scope includes floors 1, 2, 3 and 4 as well as the river level. Work to also include demolition of associated MEP scope as well. No change to existing use. B - Business. 1A construction. | $170,000 | [101073944](https://nearbypermits.com/chicago/permit/101073944/) |
| Oct 2, 2019 | Elevator | Modernization of one(1) 3000lb capacity, 6-floor, traction, passenger elevator, pursuant to the scope of work submitted.(ev009076) | $135,000 | [100844006](https://nearbypermits.com/chicago/permit/100844006/) |
| Aug 8, 2018 | Elevator | Replace hoist ropes on (1) 3000#, 6-stop passenger elevator (ev009076) | $5,500 | [100776793](https://nearbypermits.com/chicago/permit/100776793/) |
| Nov 7, 2008 | Alteration or repair | Re-glaze 8-to 10 windows, east elevation 2 - 5th floors s.a.e, subject to field inspection. | $15,000 | [100266479](https://nearbypermits.com/chicago/permit/100266479/) |
| Nov 16, 2006 | Roofing | Remove / replace existing roof covering. No structual work. All work same as existing. | $11,000 | [100149151](https://nearbypermits.com/chicago/permit/100149151/) |
| Nov 16, 2006 | Alteration or repair | Lobby and storefront remodeling; replacement of cabinets and finishes. | $50,000 | [100093324](https://nearbypermits.com/chicago/permit/100093324/) |

## Within ¼ mi since May 1, 2026

305 permits in the circle (the newest 300 listed). From our copy of the city's data (last 24 months).

### Next door (under 250 ft), 12 permits

| Date | Address | Distance | Type | Work | Cost | Permit |
|---|---|---|---|---|---|---|
| Oct 2, 2026 | [150 N Wacker Dr](https://nearbypermits.com/chicago/address/150-n-wacker-dr/) | 90 ft S | Alteration or repair | Self cert 2019 CBRC: interior alterations to existing 20th floor office space - suite 2020. Work to include new non load bearing partitions, plumbing, electrical and mechanical work as per plans. (1A construction. B-business) | $770,000 | [101088418](https://nearbypermits.com/chicago/permit/101088418/) |
| Sep 10, 2026 | [155 N Wacker Dr](https://nearbypermits.com/chicago/address/155-n-wacker-dr/) | 150 ft E | Fire systems | Fire alarm: repair existing system. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: no. Monitoring type: supervising station. Specific location: 16th floor suite 1680. | Not listed | [B200480321](https://nearbypermits.com/chicago/permit/B200480321/) |
| Aug 13, 2026 | [155 N Wacker Dr](https://nearbypermits.com/chicago/address/155-n-wacker-dr/) | 150 ft E | Fire systems | Fire alarm: repair existing system. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: no. Monitoring type: supervising station. Specific location: 5th, 6th, 7th floors. | Not listed | [B200480500](https://nearbypermits.com/chicago/permit/B200480500/) |
| Sep 9, 2026 | [150 N Wacker Dr](https://nearbypermits.com/chicago/address/150-n-wacker-dr/) | 90 ft S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 9/9/2026. End date: 9/9/2027. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and ma | Not listed | [B200510964](https://nearbypermits.com/chicago/permit/B200510964/) |
| Aug 1, 2026 | [155 N Wacker Dr](https://nearbypermits.com/chicago/address/155-n-wacker-dr/) | 150 ft E | Fire systems | Fire alarm: modification of existing system. Associated building permit:101080886. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: supervising station. Specific location: 2nd floor. | Not listed | [B200476952](https://nearbypermits.com/chicago/permit/B200476952/) |
| Jun 17, 2026 | [150 N Wacker Dr](https://nearbypermits.com/chicago/address/150-n-wacker-dr/) | 90 ft S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101083369. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 21st floor. | Not listed | [B200472661](https://nearbypermits.com/chicago/permit/B200472661/) |
| Jun 3, 2026 | [155 N Wacker Dr](https://nearbypermits.com/chicago/address/155-n-wacker-dr/) | 150 ft E | Elevator | Replacement of governor cable on one(1) 4000lb capacity, 46-floor, 1400fpm, passenger elevator(h8), pursuant to the scope of work submitted.(100233980) | Not listed | [101084265](https://nearbypermits.com/chicago/permit/101084265/) |
| May 18, 2026 | [150 N Wacker Dr](https://nearbypermits.com/chicago/address/150-n-wacker-dr/) | 90 ft S | Alteration or repair | Self-cert 2019 CBRC - tenant buildout of 1,330 sqft for business office on the 21st floor, including alterations to plumbing, electrical, and mechanical. (Occupancy group B; type IA construction) | $190,000 | [101083369](https://nearbypermits.com/chicago/permit/101083369/) |
| May 18, 2026 | [155 N Wacker Dr](https://nearbypermits.com/chicago/address/155-n-wacker-dr/) | 150 ft E | Alteration or repair | Self-cert 2019 CBRC: alterations to existing office space, suite 1680. Interior work only. (Occupancy group B - business; construction type 1a) | $450,000 | [101080886](https://nearbypermits.com/chicago/permit/101080886/) |
| May 13, 2026 | [150 N Wacker Dr](https://nearbypermits.com/chicago/address/150-n-wacker-dr/) | 90 ft S | Grading | Concrete masonry repair / replacemnt: 350sq. FT., Excavation = no. Location: south elevation. | $670,000 | [B200469443](https://nearbypermits.com/chicago/permit/B200469443/) |
| May 12, 2026 | [155 N Wacker Dr](https://nearbypermits.com/chicago/address/155-n-wacker-dr/) | 150 ft E | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: suite 1680. | $10,000 | [B200470241](https://nearbypermits.com/chicago/permit/B200470241/) |
| May 12, 2026 | [150 N Wacker Dr](https://nearbypermits.com/chicago/address/150-n-wacker-dr/) | 90 ft S | Scaffold or sidewalk shed | Temporary scaffolding: qty: 2, max. Length: 75 FT., max. Height: 375 FT. Location: south elevation. Permit expiration date: 365 days from permit issued date this permit is not valid without corresponding cdot public way permit. | Not listed | [B200469449](https://nearbypermits.com/chicago/permit/B200469449/) |

### This block (250 to 1,000 ft), 163 permits

| Date | Address | Distance | Type | Work | Cost | Permit |
|---|---|---|---|---|---|---|
| Oct 5, 2026 | [150 N Riverside Plz](https://nearbypermits.com/chicago/address/150-n-riverside-plz/) | 350 ft W | Alteration or repair | Self cert 2019 CBRC: structural peer review included. Interior demo of existing stair between floors 22 and 23 and structural infill only in suite 2200. 1A construction, occupancy b-business. | $362,613 | [101088841](https://nearbypermits.com/chicago/permit/101088841/) |
| Oct 5, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Sign | Face lit channel letters/logo reading "transwestern" | $3,500 | [101086981](https://nearbypermits.com/chicago/permit/101086981/) |
| Oct 5, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Sign | Flat cut out stainless steel letters/log reading "transwestern" | $1,000 | [101086978](https://nearbypermits.com/chicago/permit/101086978/) |
| Sep 29, 2026 | [150 N Riverside Plz](https://nearbypermits.com/chicago/address/150-n-riverside-plz/) | 350 ft W | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: apollo care -34th floor. | $14,500 | [B200513556](https://nearbypermits.com/chicago/permit/B200513556/) |
| Sep 29, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Fire systems | Fire alarm: modification of existing system. Associated building permit:101082862. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: city fire alarm box connection. Specific location: floor 32 & 33. | Not listed | [B200511237](https://nearbypermits.com/chicago/permit/B200511237/) |
| Aug 6, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Fire systems | Fire alarm: modification of existing system. Associated building permit:101082862. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 33rd floor. | Not listed | [B200479840](https://nearbypermits.com/chicago/permit/B200479840/) |
| Sep 28, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Electrical | For permit 101085759: replacement electrical contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200513533](https://nearbypermits.com/chicago/permit/B200513533/) |
| Jul 30, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Electrical | For permit 101084515: replacement electrical contractor. Replacement general contractor. Replacement plumbing contractor. Replacement other contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200479403](https://nearbypermits.com/chicago/permit/B200479403/) |
| Sep 28, 2026 | [20 N Wacker Dr](https://nearbypermits.com/chicago/address/20-n-wacker-dr/) | 860 ft S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 10/1/2026. End date: 10/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and | Not listed | [B200512954](https://nearbypermits.com/chicago/permit/B200512954/) |
| Aug 19, 2026 | [20 N Wacker Dr](https://nearbypermits.com/chicago/address/20-n-wacker-dr/) | 860 ft S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 9/1/2026. End date: 10/1/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and m | Not listed | [B200507451](https://nearbypermits.com/chicago/permit/B200507451/) |
| Sep 28, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Alteration or repair | Self cert 2019 CBRC: interior alterations to third floor office space. Work to include demo, new partitions. Plumbing, electrical and mechanical work as per plans. 1A construction. B-business use | $850,000 | [101088868](https://nearbypermits.com/chicago/permit/101088868/) |
| Sep 24, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Alteration or repair | Self-cert 2019 CBRC: interior alterations to existing 32nd and 33rd office floors for tenant (michael best & friedrich llp) as per plans. Work to include demolition, new partitions, doors and hardware, lighting, ceilings, mechanical, electrical, and plumbing. No structural work. No change in use. (C | $1,610,000 | [101086901](https://nearbypermits.com/chicago/permit/101086901/) |
| Sep 23, 2026 | [101 N Wacker Dr](https://nearbypermits.com/chicago/address/101-n-wacker-dr/) | 580 ft S | Scaffold or sidewalk shed | Temporary scaffolding: qty: 2, max. Length: 148 FT., max. Height: 297 FT. Location: north elevation. Permit expiration date: 365 days from permit issued date this permit is not valid without corresponding cdot public way permit. | Not listed | [B200512955](https://nearbypermits.com/chicago/permit/B200512955/) |
| Sep 23, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Alteration or repair | Self-cert 2019 CBRC: interior alterations to existing office suite, suites 300 and 400. No exterior work. No work to egress system. (Occupancy group b-business; construction type 1a) | $1,313,800 | [101087262](https://nearbypermits.com/chicago/permit/101087262/) |
| Sep 22, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Alteration or repair | Self cert 2019 CBRC: structural peer review included. Interior alteration of an existing unoccupied portion of experience center in 5th floor office suite. Work to include selective interior non-structural demolition, structural support for equipment, non-structural partitions, doors, ceilings, ligh | $150,000 | [101087407](https://nearbypermits.com/chicago/permit/101087407/) |
| Sep 21, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Plumbing | For permit 101085541: replacement other contractor. Replacement plumbing contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200512314](https://nearbypermits.com/chicago/permit/B200512314/) |
| Sep 21, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Electrical | Low voltage/communication electrical work. Install other. Specific location: 37th floor. | $28,000 | [B200512282](https://nearbypermits.com/chicago/permit/B200512282/) |
| Sep 7, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 36th floor. | $45,000 | [B200510628](https://nearbypermits.com/chicago/permit/B200510628/) |
| Aug 21, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Electrical | Low voltage/communication electrical work. Install audio. Specific location: audio visual pull and trim. | $33,948 | [B200507722](https://nearbypermits.com/chicago/permit/B200507722/) |
| Sep 16, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Electrical | Low voltage/communication electrical work. Install security. Specific location: unit 3200. | $42,000 | [B200511786](https://nearbypermits.com/chicago/permit/B200511786/) |
| Sep 16, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 10th floor. | $5,000 | [B200511182](https://nearbypermits.com/chicago/permit/B200511182/) |
| Sep 16, 2026 | [150 N Riverside Plz](https://nearbypermits.com/chicago/address/150-n-riverside-plz/) | 350 ft W | Alteration or repair | Self cert 2019 CBRC: interior demo only to 23rd floor. All work as per plans. 1A construction, occupancy b-business. | $280,000 | [101088281](https://nearbypermits.com/chicago/permit/101088281/) |
| Sep 16, 2026 | [100 N Riverside Plz](https://nearbypermits.com/chicago/address/100-n-riverside-plz/) | 690 ft SW | Alteration or repair | Self-cert 2019 CBRC: demolition of interior office suite on floor 19 in an existing 36 story building (occupancy group B / type 1a construction) | $388,960 | [101084367](https://nearbypermits.com/chicago/permit/101084367/) |
| Sep 15, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101084635. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: suite 610. | Not listed | [B200508144](https://nearbypermits.com/chicago/permit/B200508144/) |
| Sep 4, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101082693. Affects: 0 dwelling units; 3 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: floors 28 29 30. | Not listed | [B200479019](https://nearbypermits.com/chicago/permit/B200479019/) |
| Aug 3, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101082693. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: city fire alarm box connection. Specific location: office floors 28 & 29. | Not listed | [B200479288](https://nearbypermits.com/chicago/permit/B200479288/) |
| Aug 3, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101079691. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 1st floor. | Not listed | [B200476956](https://nearbypermits.com/chicago/permit/B200476956/) |
| Sep 14, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Electrical | For permit 101086846: replacement electrical contractor. Replacement other contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200511120](https://nearbypermits.com/chicago/permit/B200511120/) |
| Sep 9, 2026 | [225 W Wacker Dr](https://nearbypermits.com/chicago/address/225-w-wacker-dr/) | 980 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101084930. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 9th, 10th, 11th, 12th floors. | Not listed | [B200508777](https://nearbypermits.com/chicago/permit/B200508777/) |
| Aug 27, 2026 | [225 W Wacker Dr](https://nearbypermits.com/chicago/address/225-w-wacker-dr/) | 980 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101085503. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 16th floor - suite 1650. | Not listed | [B200481886](https://nearbypermits.com/chicago/permit/B200481886/) |
| Sep 9, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101078936. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: supervising station. Specific location: 37th floor. | Not listed | [B200508195](https://nearbypermits.com/chicago/permit/B200508195/) |
| Aug 24, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101078854. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 22nd floor. | Not listed | [B200473951](https://nearbypermits.com/chicago/permit/B200473951/) |
| Jul 23, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Fire systems | Fire alarm: modification of existing system. Associated building permit:b200477128. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 37th floor. | Not listed | [B200478047](https://nearbypermits.com/chicago/permit/B200478047/) |
| Sep 4, 2026 | [150 N Riverside Plz](https://nearbypermits.com/chicago/address/150-n-riverside-plz/) | 350 ft W | Alteration or repair | Self cert 2019 CBRC: interior alterations to existing 34th floor office space - suite 3400. No change to existing use. (Business / 1a) | $350,000 | [101086762](https://nearbypermits.com/chicago/permit/101086762/) |
| Sep 3, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Electrical | Low voltage/communication electrical work. Alter existing data/video. Specific location: 00033. | $2,200 | [B200510109](https://nearbypermits.com/chicago/permit/B200510109/) |
| Aug 19, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 29th floor. | $130,000 | [B200507987](https://nearbypermits.com/chicago/permit/B200507987/) |
| Jul 8, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Electrical | Low voltage/communication electrical work. Alter existing other. Specific location: 16th floor. | $48,200 | [B200477878](https://nearbypermits.com/chicago/permit/B200477878/) |
| Sep 3, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Fire systems | Fire alarm: modification of existing system. Associated building permit:101082004. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 27th floor. | Not listed | [B200479430](https://nearbypermits.com/chicago/permit/B200479430/) |
| Sep 1, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Fire systems | Fire alarm: modification of existing system. Associated building permit:101085759. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 21st floor. | Not listed | [B200507914](https://nearbypermits.com/chicago/permit/B200507914/) |
| Aug 31, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Fire systems | Fire alarm: modification of existing system. Associated building permit:b200479403. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 19th floor. | Not listed | [B200507099](https://nearbypermits.com/chicago/permit/B200507099/) |
| Aug 25, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Fire systems | Fire alarm: modification of existing system. Associated building permit:101084304. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 19th floor. | Not listed | [B200479916](https://nearbypermits.com/chicago/permit/B200479916/) |
| Aug 6, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Fire systems | Fire alarm: modification of existing system. Associated building permit:101083098. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 18th floor. | Not listed | [B200478167](https://nearbypermits.com/chicago/permit/B200478167/) |
| Sep 2, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101069893. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: doors 2201, 2217 and 2231. | Not listed | [B200506721](https://nearbypermits.com/chicago/permit/B200506721/) |
| Aug 11, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101084236. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: city fire alarm box connection. Specific location: partial 20th floor. | Not listed | [B200479991](https://nearbypermits.com/chicago/permit/B200479991/) |
| Aug 3, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101084489. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: city fire alarm box connection. Specific location: partial 22nd floor. | Not listed | [B200478953](https://nearbypermits.com/chicago/permit/B200478953/) |
| Jul 28, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101056158. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 33rd floor. | Not listed | [B200477781](https://nearbypermits.com/chicago/permit/B200477781/) |
| Jul 6, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101081048. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 27th and 28th floor. | Not listed | [B200475088](https://nearbypermits.com/chicago/permit/B200475088/) |
| Sep 2, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101084420. Affects: 0 dwelling units; 2 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 36th & 37th floor maglocks. | Not listed | [B200480310](https://nearbypermits.com/chicago/permit/B200480310/) |
| Sep 2, 2026 | [101 N Wacker Dr](https://nearbypermits.com/chicago/address/101-n-wacker-dr/) | 580 ft S | Roofing | Scope: plaza repairs: includes repairs to concrete, waterproofing, railing replacement, column encasement reinforcement and cmu wall repair at parking garage. Locations: 0 residential unit(s), 0 non-residential unit(s), exterior work, existing plaza area. | $1,232,995 | [B200478836](https://nearbypermits.com/chicago/permit/B200478836/) |
| Sep 1, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Fire systems | Fire alarm: repair existing system. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: basement. | Not listed | [B200506696](https://nearbypermits.com/chicago/permit/B200506696/) |
| Aug 31, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 96. Lighting outlets: 0. Specific location: 37th floor. | $10,600 | [B200509731](https://nearbypermits.com/chicago/permit/B200509731/) |
| Aug 27, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 28. Lighting outlets: 0. Specific location: 37th floor. | $3,960 | [B200509298](https://nearbypermits.com/chicago/permit/B200509298/) |
| Aug 14, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 72. Lighting outlets: 0. Specific location: 22nd floor. | $15,200 | [B200507422](https://nearbypermits.com/chicago/permit/B200507422/) |
| Aug 31, 2026 | [20 N Wacker Dr](https://nearbypermits.com/chicago/address/20-n-wacker-dr/) | 860 ft S | Alteration or repair | Tuckpointing and unit masonry repair / replacement: 5100 SQ. FT., Lintel qty. 0, MAX. Length 0. Location: portico columns. | $125,000 | [B200480188](https://nearbypermits.com/chicago/permit/B200480188/) |
| Aug 26, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Alteration or repair | Self-cert 2019 CBRC: demolition of interior suite on floor 1 in an existing 30 story building, including repair of existing exterior storefront (occupancy group B / type 1a construction) | $68,460 | [101086927](https://nearbypermits.com/chicago/permit/101086927/) |
| Aug 25, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 200. Lighting outlets: 0. Specific location: 37th floor. | $21,200 | [B200508410](https://nearbypermits.com/chicago/permit/B200508410/) |
| Aug 25, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 304. Lighting outlets: 0. Specific location: 36th floor. | $32,200 | [B200508403](https://nearbypermits.com/chicago/permit/B200508403/) |
| Aug 25, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Alteration or repair | Selfcert 2019 CBRC: interior alterations to existing 10th floor office space - suite 1000. No change to existing use. (Business / 1a) | $220,000 | [101086297](https://nearbypermits.com/chicago/permit/101086297/) |
| Aug 19, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 8/19/2026. End date: 8/19/2027. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and  | Not listed | [B200507997](https://nearbypermits.com/chicago/permit/B200507997/) |
| Aug 19, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 27th floor. | $140,000 | [B200507982](https://nearbypermits.com/chicago/permit/B200507982/) |
| Jul 21, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 19th floor. | $90,000 | [B200479468](https://nearbypermits.com/chicago/permit/B200479468/) |
| Aug 19, 2026 | [200 W Randolph St](https://nearbypermits.com/chicago/address/200-w-randolph-st/) | 880 ft E | Sign | Existing window vinyl graphics permit submitted for zoning compliance review. 1 Vertical window sign. | $500 | [101082162](https://nearbypermits.com/chicago/permit/101082162/) |
| Aug 19, 2026 | [200 W Randolph St](https://nearbypermits.com/chicago/address/200-w-randolph-st/) | 880 ft E | Sign | Existing window vinyl graphics permit submitted for zoning compliance review. 1 Vertical window sign. | $500 | [101082161](https://nearbypermits.com/chicago/permit/101082161/) |
| Aug 19, 2026 | [200 W Randolph St](https://nearbypermits.com/chicago/address/200-w-randolph-st/) | 880 ft E | Sign | Existing window vinyl graphics permit submitted for zoning compliance review. 1 Vertical window sign. | $500 | [101082160](https://nearbypermits.com/chicago/permit/101082160/) |
| Aug 19, 2026 | [200 W Randolph St](https://nearbypermits.com/chicago/address/200-w-randolph-st/) | 880 ft E | Sign | Existing window vinyl graphics permit submitted for zoning compliance review. 1 Vertical window sign. | $500 | [101082159](https://nearbypermits.com/chicago/permit/101082159/) |
| Aug 19, 2026 | [200 W Randolph St](https://nearbypermits.com/chicago/address/200-w-randolph-st/) | 880 ft E | Sign | Install of a static canopy sign for pita pita mediterranian grill | $4,083 | [101069159](https://nearbypermits.com/chicago/permit/101069159/) |
| Aug 17, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Alteration or repair | Self cert 2019 CBRC: interior alterations to existing NE corner 36th floor office space. Work to include new non load bearing partitions, plumbing, electrical and mechanical work as per plans. (1A construction. B-business use) | $1,019,364 | [101086846](https://nearbypermits.com/chicago/permit/101086846/) |
| Aug 17, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Self cert 2019 CBRC: structrual peer review included. Interior alterations to first floor lobby to replace an existing reception desk and add a new open-ceiling glass conference room enclosure on the mezzanine level. Replacement of one side of existing handrail at stairs from lobby to mezzanine leve | $612,000 | [101083912](https://nearbypermits.com/chicago/permit/101083912/) |
| Aug 17, 2026 | [225 W Randolph St](https://nearbypermits.com/chicago/address/225-w-randolph-st/) | 720 ft E | Alteration or repair | Spr 2019 CBC: interior alterations for new mdf room in existing 13th floor office space as per plans (occupancy B, type IA construction) | $430,000 | [101082707](https://nearbypermits.com/chicago/permit/101082707/) |
| Aug 14, 2026 | [225 W Washington St](https://nearbypermits.com/chicago/address/225-w-washington-st/) | 940 ft SE | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: suite 2300. | $33,981 | [B200507334](https://nearbypermits.com/chicago/permit/B200507334/) |
| Aug 14, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Sign | Just salad: internally illuminated face-lit suspended window sign mounted, interior mounted (n wacker dr elevation) - 4'-6" h x 2'-0" W (9 SQ ft) | $3,500 | [101086655](https://nearbypermits.com/chicago/permit/101086655/) |
| Aug 13, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Sign | Just salad: internally illuminated face-lit suspended window sign mounted, interior mounted (w randolph st elevation) - 3'-4" h x 9'-5" W (31 SQ ft) | $8,500 | [101086658](https://nearbypermits.com/chicago/permit/101086658/) |
| Aug 14, 2026 | [225 W Wacker Dr](https://nearbypermits.com/chicago/address/225-w-wacker-dr/) | 980 ft NE | Alteration or repair | Self-cert 2019 CBC: interior alteration of existing offices on floors 9, 10, 11 & 12. Area of work 23,043 SQ FT. No change to existing group B, business occupancy or existing construction type i-a. This permit replaces 101077059, which is void due to change in scope of work greater than 25%. | $2,880,375 | [101084930](https://nearbypermits.com/chicago/permit/101084930/) |
| Aug 13, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Sign | Just salad: internally illuminated face-lit suspended sign, exterior mounted (n wacker dr elevation) - 2'-9" h x 14'-0" W (39 SQ ft) | $12,000 | [101086657](https://nearbypermits.com/chicago/permit/101086657/) |
| Aug 13, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Sign | Just salad: vinyl window sign (n wacker dr elevation) - 6'-0" h x 4'-9" W (29 SQ ft) | $650 | [101086656](https://nearbypermits.com/chicago/permit/101086656/) |
| Aug 12, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Elevator | Replacement of hoist cables on one(1) 3500lb capacity, 35-floor, 800fpm, passenger elevator(#8), pursuant to the scope of work submitted.(100594928) | Not listed | [101087200](https://nearbypermits.com/chicago/permit/101087200/) |
| Aug 11, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Alteration or repair | Self-cert 2019 CBRC: alteration of existing vacant suite on floor 1 in an existing 30 story building (occupancy group B / type 1a construction) | $97,000 | [101085373](https://nearbypermits.com/chicago/permit/101085373/) |
| Aug 6, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Self cert 2019 CBRC: commercial tenant improvement on 8th floor including installation of new acoustic office pod and associated electrical improvements. No structural, mechanical or plumbing.(1a construction. B-business use) | $39,000 | [101086688](https://nearbypermits.com/chicago/permit/101086688/) |
| Aug 6, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Alteration or repair | Self-cert 2019 CBRC: interior alterations to existing 32nd, 33rd, and 34th office floors as per plans. Work to include new open office and private offices, conference rooms, multipurpose rooms, pantries, and renovation of existing core restrooms. Demolition and construction of non-load bearing parti | $7,323,185 | [101085541](https://nearbypermits.com/chicago/permit/101085541/) |
| Aug 3, 2026 | [225 W Washington St](https://nearbypermits.com/chicago/address/225-w-washington-st/) | 940 ft SE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101082797. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: suite 2300. | Not listed | [B200479590](https://nearbypermits.com/chicago/permit/B200479590/) |
| Jun 9, 2026 | [225 W Washington St](https://nearbypermits.com/chicago/address/225-w-washington-st/) | 940 ft SE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101077898. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: city fire alarm box connection. Specific location: floor 13. | Not listed | [B200472301](https://nearbypermits.com/chicago/permit/B200472301/) |
| Jun 5, 2026 | [225 W Washington St](https://nearbypermits.com/chicago/address/225-w-washington-st/) | 940 ft SE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101077079. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: city fire alarm box connection. Specific location: floor 5. | Not listed | [B200471708](https://nearbypermits.com/chicago/permit/B200471708/) |
| Aug 3, 2026 | [150 N Riverside Plz](https://nearbypermits.com/chicago/address/150-n-riverside-plz/) | 350 ft W | Elevator | Replace comp. Ropes on eg passenger elevator car h9, 4000lbs capacity, 53 floors, subject to city of chicago dept. Of buildings elevator bureau inspection (a/p #100624647). | Not listed | [101086633](https://nearbypermits.com/chicago/permit/101086633/) |
| Jul 31, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 399. Lighting outlets: 0. Specific location: 29th floor. | $35,600 | [B200480996](https://nearbypermits.com/chicago/permit/B200480996/) |
| Jun 16, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Electrical | Line voltage electrical work. Add 1 circuits to existing 200 amp service disconnecting means. Receptacle outlets: 40. Lighting outlets: 2. Specific location: floor 29. | $767,160 | [B200473336](https://nearbypermits.com/chicago/permit/B200473336/) |
| Jul 29, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Alteration or repair | Self cert 2019 CBRC: interior demo only to suite 950. Work to include demolition of non-structuralpartitions, doors/frames, ceiling & lighting, plumbing fixtures, finishes and millwork. All work as per plans. 1A construction. B-business use | $150,000 | [101086501](https://nearbypermits.com/chicago/permit/101086501/) |
| Jul 29, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Alteration or repair | Self-cert 2019 CBRC: interior alterations in an existing office building on the 9th floor to divide office suite 925 into two office suites, 925 and 900. Work includes construction of a demising wall, non-load-bearing partitions, millwork, finishes, ceilings, and associated electrical, ventilation a | $307,000 | [101083737](https://nearbypermits.com/chicago/permit/101083737/) |
| Jul 27, 2026 | [225 W Wacker Dr](https://nearbypermits.com/chicago/address/225-w-wacker-dr/) | 980 ft NE | Elevator | Hoist cable replacement on one(1) 3500lb capacity, 17-floor, 550fpm, passenger elevator(pe1), pursuant to the scope of work submitted.(ev011506) | Not listed | [101085968](https://nearbypermits.com/chicago/permit/101085968/) |
| Jul 24, 2026 | [111 N Canal St](https://nearbypermits.com/chicago/address/111-n-canal-st/) | 790 ft SW | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 242. Lighting outlets: 0. Specific location: 12th floor. | $32,400 | [B200479151](https://nearbypermits.com/chicago/permit/B200479151/) |
| Jul 24, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Fire systems | Fire alarm: modification of existing system. Associated building permit:101081463. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 29th floor. | Not listed | [B200478154](https://nearbypermits.com/chicago/permit/B200478154/) |
| Jul 13, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Fire systems | Fire alarm: modification of existing system. Associated building permit:101079655. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: city fire alarm box connection. Specific location: floor 16. | Not listed | [B200476982](https://nearbypermits.com/chicago/permit/B200476982/) |
| Jun 9, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Fire systems | Fire alarm: modification of existing system. Associated building permit:101079655. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 16th floor. | Not listed | [B200472412](https://nearbypermits.com/chicago/permit/B200472412/) |
| Jul 23, 2026 | [20 N Wacker Dr](https://nearbypermits.com/chicago/address/20-n-wacker-dr/) | 860 ft S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 8/1/2026. End date: 8/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and m | Not listed | [B200479232](https://nearbypermits.com/chicago/permit/B200479232/) |
| Jun 23, 2026 | [20 N Wacker Dr](https://nearbypermits.com/chicago/address/20-n-wacker-dr/) | 860 ft S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 7/1/2026. End date: 7/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and m | Not listed | [B200475112](https://nearbypermits.com/chicago/permit/B200475112/) |
| Jul 23, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Standard plan 2019 CBRC: interior alterations to 27th floor citrin cooperman office space. Work to include selective demolition, new partitions, mechanical, electrical and plumbing as per plans. No change in use. B-business. 1A construction | $1,800,000 | [101082004](https://nearbypermits.com/chicago/permit/101082004/) |
| Jul 22, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 37th floor. | $85,000 | [B200479597](https://nearbypermits.com/chicago/permit/B200479597/) |
| Jul 22, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Alteration or repair | Self-cert 2019 CBRC: interior alterations to existing 6th floor office space - suite 610. No change to existing use. (Business / 1a) | $110,000 | [101084635](https://nearbypermits.com/chicago/permit/101084635/) |
| Jul 17, 2026 | [20 N Wacker Dr](https://nearbypermits.com/chicago/address/20-n-wacker-dr/) | 860 ft S | Alteration or repair | Tuckpointing and unit masonry repair / replacement: 15500 SQ. FT., Lintel qty. 0, MAX. Length 0. Location: west elevation exterior facade. | $200,000 | [B200469851](https://nearbypermits.com/chicago/permit/B200469851/) |
| Jul 14, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Self cert 2019 CBRC: interior alterations to existing 21st floor office space spec suite 2125. Work to include new non load bearing partitions, electrical, plumbing and mechanical work as per plans. (1A construction. B-business use) | $850,000 | [101085759](https://nearbypermits.com/chicago/permit/101085759/) |
| Jul 14, 2026 | [225 W Wacker Dr](https://nearbypermits.com/chicago/address/225-w-wacker-dr/) | 980 ft NE | Alteration or repair | Self cert 2019 CBC: interior alterations to existing office suite 1650 to include finish, furniture & layout upgrades as per plans (occupancy B, type IA construction) | $500,000 | [101085503](https://nearbypermits.com/chicago/permit/101085503/) |
| Jul 10, 2026 | [20 N Wacker Dr](https://nearbypermits.com/chicago/address/20-n-wacker-dr/) | 860 ft S | Fire systems | Fire alarm: modification of existing system. Associated building permit:b200470521. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 20 N wacker suite 2620. | Not listed | [B200476447](https://nearbypermits.com/chicago/permit/B200476447/) |
| Jul 8, 2026 | [165 N Canal St](https://nearbypermits.com/chicago/address/165-n-canal-st/) | 680 ft W | Scaffold or sidewalk shed | Temporary scaffolding: qty: 3, max. Length: 30 FT., max. Height: 160 FT. Location: all elevations. Permit expiration date: 365 days from permit issued date this permit is not valid without corresponding cdot public way permit. | Not listed | [B200477452](https://nearbypermits.com/chicago/permit/B200477452/) |
| Jul 8, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Plumbing | For permit 101078936: replacement plumbing contractor. Replacement other contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200477128](https://nearbypermits.com/chicago/permit/B200477128/) |
| Jul 8, 2026 | [233 W Wacker Dr](https://nearbypermits.com/chicago/address/233-w-wacker-dr/) | 940 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101075483. Affects: 0 dwelling units; 3 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: supervising station. Specific location: 72,73, 74th floors. | Not listed | [B200474777](https://nearbypermits.com/chicago/permit/B200474777/) |
| Jul 7, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Plumbing | For permit 101080880: replacement plumbing contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200477574](https://nearbypermits.com/chicago/permit/B200477574/) |
| Jul 7, 2026 | [225 W Wacker Dr](https://nearbypermits.com/chicago/address/225-w-wacker-dr/) | 980 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101082022. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 22nd floor - suite 2250. | Not listed | [B200474912](https://nearbypermits.com/chicago/permit/B200474912/) |
| Jul 6, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Alteration or repair | Sc 2019 CBRC: interior alterations to existing commercial space in suite #150 on first floor within existing multi-story building. Alterations include interior demolition, mechanical, plumbing, electrical, structural and architectural work. No change to common areas. No change in use. (Occ grp: B, c | $693,000 | [101083358](https://nearbypermits.com/chicago/permit/101083358/) |
| Jul 1, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Electrical | Low voltage/communication electrical work. Install other. Specific location: floor 1 suite 1650. | $134,515 | [B200477041](https://nearbypermits.com/chicago/permit/B200477041/) |
| Jun 17, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Electrical | Low voltage/communication electrical work. Install telephone. Specific location: 16th floor. | $83,214 | [B200475089](https://nearbypermits.com/chicago/permit/B200475089/) |
| May 11, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Electrical | Low voltage/communication electrical work. Alter existing security. Specific location: 45th floor - 2 units. | $6,000 | [B200470074](https://nearbypermits.com/chicago/permit/B200470074/) |
| Jun 30, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Alteration or repair | Self cert 2019 CBRC: interior alterations to office suite 3125. Work to include demo, new partitions, electrical, and mechanical as per plans. B-business, 1a construction. | $318,290 | [101083624](https://nearbypermits.com/chicago/permit/101083624/) |
| Jun 29, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Self-cert 2019 CBRC: interior alterations to existing office spaces on floors 27 to 34. Scope includes isolating existing chilled water riser infrastructure to each level, demolishing existing cwr on floors no longer occupied, and adding new pumps and piping for floors that were isolated that are cu | $70,000 | [101085008](https://nearbypermits.com/chicago/permit/101085008/) |
| Jun 25, 2026 | [101 N Wacker Dr](https://nearbypermits.com/chicago/address/101-n-wacker-dr/) | 580 ft S | Alteration or repair | *Self certification 2019 cbrc*: interior *demo only* work for suite 300 as per plans. No change in use. B-business and construction type IA. | $134,000 | [101084278](https://nearbypermits.com/chicago/permit/101084278/) |
| Jun 23, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Other | For permit 101082693: replacement general contractor. Replacement other contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200475168](https://nearbypermits.com/chicago/permit/B200475168/) |
| Jun 23, 2026 | [225 W Washington St](https://nearbypermits.com/chicago/address/225-w-washington-st/) | 940 ft SE | Alteration or repair | Self certification 2019 cbrc-- interior build out -existing demised premises -former take out coffee- new salad bar concept - take out - no seating | $65,000 | [101084406](https://nearbypermits.com/chicago/permit/101084406/) |
| Jun 23, 2026 | [150 N Riverside Plz](https://nearbypermits.com/chicago/address/150-n-riverside-plz/) | 350 ft W | Sign | Install one(1) 7'5" high x 3'4" wide double-faced externally illuminated freestanding directional sign, connecting to existing electric on the south side of the zoning lot. | $22,530 | [101083934](https://nearbypermits.com/chicago/permit/101083934/) |
| Jun 22, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Electrical | Low voltage/communication electrical work. Install other. Specific location: 5th floor. | $69,300 | [B200474634](https://nearbypermits.com/chicago/permit/B200474634/) |
| May 6, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Electrical | Low voltage/communication electrical work. Install security. Specific location: floor 5. | $17,000 | [B200469436](https://nearbypermits.com/chicago/permit/B200469436/) |
| May 5, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: floor 5. | Not listed | [B200468817](https://nearbypermits.com/chicago/permit/B200468817/) |
| Jun 22, 2026 | [208 W Washington St](https://nearbypermits.com/chicago/address/208-w-washington-st/) | 980 ft SE | Scaffold or sidewalk shed | Temporary scaffolding: qty: 1, max. Length: 27 FT., max. Height: 180 FT. Location: north elevation. Permit expiration date: 365 days from permit issued date | Not listed | [B200473961](https://nearbypermits.com/chicago/permit/B200473961/) |
| Jun 22, 2026 | [208 W Washington St](https://nearbypermits.com/chicago/address/208-w-washington-st/) | 980 ft SE | Alteration or repair | Tuckpointing and unit masonry repair / replacement: 7500 SQ. FT., Lintel qty. 0, MAX. Length 0. Parapet rebuilding: 236 SQ. FT. Location: north elevation. | $597,028 | [B200473955](https://nearbypermits.com/chicago/permit/B200473955/) |
| Jun 19, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Scaffold or sidewalk shed | Temporary scaffolding: qty: 1, max. Length: 30 FT., max. Height: 40 FT. Location: exterior facade. Permit expiration date: 365 days from permit issued date this permit is not valid without corresponding cdot public way permit. | Not listed | [B200473534](https://nearbypermits.com/chicago/permit/B200473534/) |
| Jun 17, 2026 | [225 W Wacker Dr](https://nearbypermits.com/chicago/address/225-w-wacker-dr/) | 980 ft NE | Alteration or repair | Scope: nonstructural interior alteration to include removal of storage room and portion of demising wall, install new partition, door, and millwork with electrical for new receptables. Locations: 0 residential unit(s), 1 non-residential unit(s), interior office suite. | $45,000 | [B200474296](https://nearbypermits.com/chicago/permit/B200474296/) |
| Jun 17, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Selfcert 2019 CBRC: interior alterations to existing 19th floor office space. No change to existing use. (Occupancy B / construction type 1a) | $3,000,000 | [101084515](https://nearbypermits.com/chicago/permit/101084515/) |
| Jun 17, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Alteration or repair | Selfcert 2019 CBRC: interior alterations to existing 29th floor office space. Acar included. No change to existing use. Business/1a | $2,170,000 | [101081463](https://nearbypermits.com/chicago/permit/101081463/) |
| Jun 16, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Selfcert 2019 CBRC: interior alterations to existing 31st and 32nd floor office space to include the removal of an internal stair. Structural peer review included. No change to existing use. (Occupancy B / construction type 1a) | $35,000 | [101084468](https://nearbypermits.com/chicago/permit/101084468/) |
| Jun 15, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Alteration or repair | Self-cert 2019 CBRC - tenant buildout of 1,287 sqft for business office on the 22nd floor. (Occupancy group B; type IA construction) | $300,000 | [101084489](https://nearbypermits.com/chicago/permit/101084489/) |
| Jun 15, 2026 | [100 N Riverside Plz](https://nearbypermits.com/chicago/address/100-n-riverside-plz/) | 690 ft SW | Alteration or repair | Self cert 2019 CBRC: revision to permit #101078820 to remove walls from permitted scope, add new doors, infill existing gypsum wall openings and add a single new gypsum wall as per plans. 1A construction, b-business occupancy | $143,844 | [101084464](https://nearbypermits.com/chicago/permit/101084464/) |
| Jun 15, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Self cert 2019 CBRC: interior alterations to existing 19th floor corridor. Work to include new non load bearing partitions, electrical and mechanical work as per plans. (1A construction. B-business use) | $75,000 | [101084304](https://nearbypermits.com/chicago/permit/101084304/) |
| Jun 15, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Alteration or repair | Self-cert 2019 CBRC - tenant buildout of 403 sqft for business office on the 20th floor. (Occupancy group B; type IA construction) | $103,465 | [101084236](https://nearbypermits.com/chicago/permit/101084236/) |
| Jun 10, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Alteration or repair | Self-cert 2019 CBRC: revision to permit #101079053 to add supplemental cooling and plumbing updates. B-business, 1a construction. No change in use. | $750,000 | [101084420](https://nearbypermits.com/chicago/permit/101084420/) |
| Jun 9, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101081048. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 27th and 28th floor. | Not listed | [B200472304](https://nearbypermits.com/chicago/permit/B200472304/) |
| Jun 9, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Alteration or repair | Self-cert 2019 CBRC: alteration of interior office suite on floor 26 in an existing 37 story building (occupancy group B / type 1a construction) | $452,650 | [101084046](https://nearbypermits.com/chicago/permit/101084046/) |
| Jun 2, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Alteration or repair | Self cert 2019 CBRC: revision to permit #101079214 to construct a temporary partition between the reception and exhibit area and for an updated lighting layout in the exhibit area. B-business occupancy. Construction type 1a | $100 | [101083703](https://nearbypermits.com/chicago/permit/101083703/) |
| Jun 1, 2026 | [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/) | 460 ft S | Fire systems | Fire alarm: repair existing system. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: supervising station. Specific location: 22nd floor. | Not listed | [B200470534](https://nearbypermits.com/chicago/permit/B200470534/) |
| May 30, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Fire systems | Fire alarm: repair existing system. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: supervising station. Specific location: 16th floor. | Not listed | [B200470287](https://nearbypermits.com/chicago/permit/B200470287/) |
| May 28, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Selfcert 2019 CBRC: interior alterations to existing basement and 19th floor office space. Scope to include level 19 panel relocation & basement panel re-feed. No change to existing use. (Occupancy business. Construction type 1a) | $17,000 | [101083712](https://nearbypermits.com/chicago/permit/101083712/) |
| May 28, 2026 | [225 W Washington St](https://nearbypermits.com/chicago/address/225-w-washington-st/) | 940 ft SE | Alteration or repair | Self-cert 2019 CBRC: interior office alteration in existing office building on the 23rd floor, to exiting office suite 2300. New partitions, doors, ceilings, lighting, millwork, and finishes throughout. Associated electrical, and mechanical work as per plans. (Occupancy group B; type 1a construction | $414,466 | [101082797](https://nearbypermits.com/chicago/permit/101082797/) |
| May 28, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Alteration or repair | Self-cert 2019 CBRC: alteration of interior office suite on floors 21 & 22 in an existing 52 story building, including infill of existing interior non-egress connecting stair (occupancy group B / type 1a construction) | $225,000 | [101082482](https://nearbypermits.com/chicago/permit/101082482/) |
| May 27, 2026 | [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/) | 310 ft NE | Electrical | Low voltage/communication electrical work. Install security. Specific location: suite 1675. | $14,800 | [B200472158](https://nearbypermits.com/chicago/permit/B200472158/) |
| May 27, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 190. Lighting outlets: 0. Specific location: 6th floor. | $24,400 | [B200472148](https://nearbypermits.com/chicago/permit/B200472148/) |
| May 27, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Elevator | Modernization of one(1) 2000lb capacity, 2-floor, 50fpm, freight elevator(#23), pursuant to the scope of work submitted.(ev007203) | $287,000 | [101083743](https://nearbypermits.com/chicago/permit/101083743/) |
| May 25, 2026 | [101 N Wacker Dr](https://nearbypermits.com/chicago/address/101-n-wacker-dr/) | 580 ft S | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 164. Lighting outlets: 0. Specific location: 20th floor. | $19,200 | [B200471903](https://nearbypermits.com/chicago/permit/B200471903/) |
| May 25, 2026 | [101 N Wacker Dr](https://nearbypermits.com/chicago/address/101-n-wacker-dr/) | 580 ft S | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 64. Lighting outlets: 0. Specific location: 19th floor. | $14,800 | [B200471902](https://nearbypermits.com/chicago/permit/B200471902/) |
| May 25, 2026 | [101 N Wacker Dr](https://nearbypermits.com/chicago/address/101-n-wacker-dr/) | 580 ft S | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 16. Lighting outlets: 0. Specific location: 1st floor. | $2,160 | [B200471897](https://nearbypermits.com/chicago/permit/B200471897/) |
| May 22, 2026 | [20 N Wacker Dr](https://nearbypermits.com/chicago/address/20-n-wacker-dr/) | 860 ft S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 6/1/2026. End date: 7/1/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and ma | Not listed | [B200471270](https://nearbypermits.com/chicago/permit/B200471270/) |
| May 20, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Addition | For permit 101081048: additional plumbing contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200471459](https://nearbypermits.com/chicago/permit/B200471459/) |
| May 20, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 18th floor. | $10,000 | [B200471457](https://nearbypermits.com/chicago/permit/B200471457/) |
| May 20, 2026 | [20 N Wacker Dr](https://nearbypermits.com/chicago/address/20-n-wacker-dr/) | 860 ft S | Alteration or repair | Scope: non-structural interior alteration to existing office suite 2620 for new open huddle and cafe area, wellness room, and entry modifications. Scope includes demo, new non-load bearing partitions, doors, lighting, millwork, finishes and associated mechanical, electrical and plumbing work. No cha | $92,000 | [B200470521](https://nearbypermits.com/chicago/permit/B200470521/) |
| May 20, 2026 | [177 N Wells St](https://nearbypermits.com/chicago/address/177-n-wells-st/) | 950 ft E | Elevator | Modernization of four(4) 3000lb capacity, (#1-#2) @ 15-floor, (#3-#4) @ 14-floor, passenger elevators, pursuant to the scope of work submitted.(ev011325) | $1,500,800 | [101083732](https://nearbypermits.com/chicago/permit/101083732/) |
| May 15, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: suite 2000. | $15,000 | [B200470540](https://nearbypermits.com/chicago/permit/B200470540/) |
| May 13, 2026 | [225 W Wacker Dr](https://nearbypermits.com/chicago/address/225-w-wacker-dr/) | 980 ft NE | Electrical | Low voltage/communication electrical work. Install security. Specific location: suite 2750. | $91,000 | [B200468992](https://nearbypermits.com/chicago/permit/B200468992/) |
| May 12, 2026 | [20 N Wacker Dr](https://nearbypermits.com/chicago/address/20-n-wacker-dr/) | 860 ft S | Scaffold or sidewalk shed | Temporary scaffolding: qty: 2, max. Length: 40 FT., max. Height: 540 FT. Location: west elevation exterior facade. Permit expiration date: 365 days from permit issued date | Not listed | [B200469840](https://nearbypermits.com/chicago/permit/B200469840/) |
| May 12, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101079465. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 20th floor - suite 2000. | Not listed | [B200468654](https://nearbypermits.com/chicago/permit/B200468654/) |
| May 12, 2026 | [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/) | 400 ft S | Alteration or repair | Self cert 2019 CBRC: interior alterations to existing office space on floors 28,29 and 30. Work to include demo, new partitions, mechanical, electrical and plumbing as per plans. 1A construction. No change to b-business occupancy. | $5,150,000 | [101082693](https://nearbypermits.com/chicago/permit/101082693/) |
| May 12, 2026 | [233 W Lake St](https://nearbypermits.com/chicago/address/233-w-lake-st/) | 670 ft NE | Alteration or repair | Structural repair to portion of 1st floor in existing restaurant in 4 story masonry mixed use building. | $25,000 | [101075864](https://nearbypermits.com/chicago/permit/101075864/) |
| May 11, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Scope: non-structural interior alterations to existing office space to convert 2 offices to conference room. Scope of work includes the installation of double doors at the entry and new pendant lighting fixtures. Locations: 0 residential unit(s), 1 non-residential unit(s), 6th floor. | $43,440 | [B200468451](https://nearbypermits.com/chicago/permit/B200468451/) |
| May 7, 2026 | [333 W Wacker Dr](https://nearbypermits.com/chicago/address/333-w-wacker-dr/) | 520 ft NE | Alteration or repair | Selfcert 2019 CBRC: interior alterations to existing 16th floor office space - suite 1650. Scope of work to include electrical, mechanical, sprinkler and plumbing work. No change to existing use. (Business / 1a) | $77,000 | [101081388](https://nearbypermits.com/chicago/permit/101081388/) |
| May 6, 2026 | [101 N Wacker Dr](https://nearbypermits.com/chicago/address/101-n-wacker-dr/) | 580 ft S | Mechanical (HVAC) | Ductwork extension/reconfiguration, hydronic piping extension/reconfiguration, repair/replacement affecting 1 systems : 4 vrf zone fan unit(daikin, fxmq48tbvju, suite 102). Electrical work under this permit = yes. Locations: 0 residential unit(s), 1 non-residential unit(s), suite 102. | $400,000 | [B200467862](https://nearbypermits.com/chicago/permit/B200467862/) |
| May 6, 2026 | [151 N Franklin St](https://nearbypermits.com/chicago/address/151-n-franklin-st/) | 550 ft E | Alteration or repair | Self cert 2019 CBRC: interior alterations to existing 18th floor office space. Work to include new non load bearing partitions, electrical and mechanical work as per plans. No structural. No plumbing. (1A construction. B-business use) | $180,000 | [101083098](https://nearbypermits.com/chicago/permit/101083098/) |
| May 5, 2026 | [444 W Lake St](https://nearbypermits.com/chicago/address/444-w-lake-st/) | 810 ft NW | Alteration or repair | Interior alterations to existing office space on the 33rd floor of a high rise building in the central business district. The scope of work includes demolition of non-load bearing partitions, new non-load bearing metal stud and drywall partitions, rework of existing led light fixtures, new low volta | $380,000 | [101082862](https://nearbypermits.com/chicago/permit/101082862/) |
| May 4, 2026 | [200 W Randolph St](https://nearbypermits.com/chicago/address/200-w-randolph-st/) | 880 ft E | Grading | Concrete masonry repair / replacemnt: 300sq. FT., Excavation = no. Location: level 6 and level 7. | $200,000 | [B200468760](https://nearbypermits.com/chicago/permit/B200468760/) |
| May 4, 2026 | [180 N Franklin St](https://nearbypermits.com/chicago/address/180-n-franklin-st/) | 500 ft NE | Grading | Concrete masonry repair / replacemnt: 200sq. FT., Excavation = no. Location: level 2 and level 3. | $200,000 | [B200468759](https://nearbypermits.com/chicago/permit/B200468759/) |

### Farther (1,000 ft to ¼ mi), 125 permits

| Date | Address | Distance | Type | Work | Cost | Permit |
|---|---|---|---|---|---|---|
| Oct 5, 2026 | [168 N Clinton St](https://nearbypermits.com/chicago/address/168-n-clinton-st/) | 0.22 mi W | Fence, wall or deck | Purpose: new/replacement installation. Wrought iron fence - 6'-0' ' (height) x 60'-0' ' (length). Chain link fence - 6'-0' ' (height) x 420'-0' ' (length). Location: 6' fence -permanant steel picket & chain link w/sc. | $34,830 | [B200512051](https://nearbypermits.com/chicago/permit/B200512051/) |
| Oct 1, 2026 | [171 W Randolph St](https://nearbypermits.com/chicago/address/171-w-randolph-st/) | 0.21 mi E | Electrical | Electrical maintenance permit. Occupancy: institutional. Start date: 10/1/2026. End date: 10/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permi | Not listed | [B200514026](https://nearbypermits.com/chicago/permit/B200514026/) |
| Sep 11, 2026 | [171 W Randolph St](https://nearbypermits.com/chicago/address/171-w-randolph-st/) | 0.21 mi E | Electrical | Electrical maintenance permit. Occupancy: institutional. Start date: 9/1/2026. End date: 10/1/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit  | Not listed | [B200509841](https://nearbypermits.com/chicago/permit/B200509841/) |
| Aug 4, 2026 | [171 W Randolph St](https://nearbypermits.com/chicago/address/171-w-randolph-st/) | 0.21 mi E | Electrical | Electrical maintenance permit. Occupancy: institutional. Start date: 8/3/2026. End date: 9/2/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit a | Not listed | [B200481129](https://nearbypermits.com/chicago/permit/B200481129/) |
| Oct 1, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Fire systems | Fire alarm: modification of existing system. Associated building permit:101085888. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: suite 1750. | Not listed | [B200510747](https://nearbypermits.com/chicago/permit/B200510747/) |
| Sep 3, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Fire systems | Fire alarm: modification of existing system. Associated building permit:b200468672. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: suite 1200. | Not listed | [B200478593](https://nearbypermits.com/chicago/permit/B200478593/) |
| Aug 25, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Fire systems | Fire alarm: modification of existing system. Associated building permit:b200460792. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 13th floor suite 1320. | Not listed | [B200481604](https://nearbypermits.com/chicago/permit/B200481604/) |
| Aug 25, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Fire systems | Fire alarm: modification of existing system. Associated building permit:101077301. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 2nd floor. | Not listed | [B200465474](https://nearbypermits.com/chicago/permit/B200465474/) |
| Aug 4, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Fire systems | Fire alarm: modification of existing system. Associated building permit:b200460792. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 13th floor suite 1310. | Not listed | [B200476081](https://nearbypermits.com/chicago/permit/B200476081/) |
| Aug 3, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Fire systems | Fire alarm: modification of existing system. Associated building permit:b200460792. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 13th floor. | Not listed | [B200476067](https://nearbypermits.com/chicago/permit/B200476067/) |
| Sep 29, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101086760. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 34th floor. | Not listed | [B200510746](https://nearbypermits.com/chicago/permit/B200510746/) |
| Sep 8, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101075928. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: city fire alarm box connection. Specific location: floor 22. | Not listed | [B200506914](https://nearbypermits.com/chicago/permit/B200506914/) |
| Sep 28, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 10/1/2026. End date: 10/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and | Not listed | [B200513492](https://nearbypermits.com/chicago/permit/B200513492/) |
| Aug 19, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 9/1/2026. End date: 10/1/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and m | Not listed | [B200508014](https://nearbypermits.com/chicago/permit/B200508014/) |
| Sep 28, 2026 | [10 S Riverside Plz](https://nearbypermits.com/chicago/address/10-s-riverside-plz/) | 0.23 mi S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101082245. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 12th floor. | Not listed | [B200480220](https://nearbypermits.com/chicago/permit/B200480220/) |
| Sep 23, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 10/1/2026. End date: 10/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and | Not listed | [B200512902](https://nearbypermits.com/chicago/permit/B200512902/) |
| Aug 27, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 9/1/2026. End date: 10/1/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and m | Not listed | [B200509235](https://nearbypermits.com/chicago/permit/B200509235/) |
| Jul 27, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 8/1/2026. End date: 8/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and m | Not listed | [B200479757](https://nearbypermits.com/chicago/permit/B200479757/) |
| Sep 22, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Alteration or repair | .Scope: nonstructural interior alteration of existing office to include removal of abandoned of HVAC components and reconfigure ductwork for new office layout with associated electrical work..locations: 0 residential unit(s), 1 non-residential unit(s), office suite on floor 26. | $170,000 | [B200509646](https://nearbypermits.com/chicago/permit/B200509646/) |
| Sep 21, 2026 | [200 N La Salle St](https://nearbypermits.com/chicago/address/200-n-la-salle-st/) | 0.25 mi E | Electrical | For permit 101087061: replacement plumbing contractor. Replacement electrical contractor. Replacement general contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200511949](https://nearbypermits.com/chicago/permit/B200511949/) |
| Sep 21, 2026 | [10 S Wacker Dr](https://nearbypermits.com/chicago/address/10-s-wacker-dr/) | 0.21 mi S | Alteration or repair | Scope: interior alterations to existing 34th floor office space- suite 3450: construct (4) new private offices, relocated lighting, new and relocated power/ communication, new millwork at collab area and break room with sink replacement, and new flooring finish at break room and collab area and asso | $151,016 | [B200511298](https://nearbypermits.com/chicago/permit/B200511298/) |
| Sep 18, 2026 | [211 W Wacker Dr](https://nearbypermits.com/chicago/address/211-w-wacker-dr/) | 0.20 mi NE | Grading | Tuckpointing and unit masonry repair / replacement: 800 SQ. FT., Lintel qty. 0, MAX. Length 0. Concrete masonry repair / replacemnt: 650sq. FT., Excavation = no. Location: north, south, east, and west exterior facade.. | $686,850 | [B200511956](https://nearbypermits.com/chicago/permit/B200511956/) |
| Sep 17, 2026 | [211 W Wacker Dr](https://nearbypermits.com/chicago/address/211-w-wacker-dr/) | 0.20 mi NE | Scaffold or sidewalk shed | Temporary scaffolding: qty: 2, max. Length: 80 FT., max. Height: 225 FT. Location: north, south, east, and west exterior facade.. Permit expiration date: 365 days from permit issued date | Not listed | [B200511761](https://nearbypermits.com/chicago/permit/B200511761/) |
| Sep 11, 2026 | [10 S Wacker Dr](https://nearbypermits.com/chicago/address/10-s-wacker-dr/) | 0.21 mi S | Alteration or repair | Self-cert 2019 CBRC: interior alterations of existing office space, suite 3425. No exterior work. No work to egress system. (Occupancy group b-business; construction type 1a) | $450,000 | [101087423](https://nearbypermits.com/chicago/permit/101087423/) |
| Sep 11, 2026 | [10 S Wacker Dr](https://nearbypermits.com/chicago/address/10-s-wacker-dr/) | 0.21 mi S | Alteration or repair | Self-cert 2019 CBRC: interior alterations of existing office space, suites 3325 and 3375. Suite 3375 to be left as white shell space. No exterior work. No work to egress system. (Occupancy group b-business; consstruction type 1a) | $1,362,000 | [101087403](https://nearbypermits.com/chicago/permit/101087403/) |
| Sep 11, 2026 | [10 S Wacker Dr](https://nearbypermits.com/chicago/address/10-s-wacker-dr/) | 0.21 mi S | Alteration or repair | Self-cert 2019: alterations to existing office space, suite 2500. No work to egress system. No exterior work. (Occupancy type b-business; construction type 1a) | $600,000 | [101087339](https://nearbypermits.com/chicago/permit/101087339/) |
| Sep 11, 2026 | [549 W Randolph St](https://nearbypermits.com/chicago/address/549-w-randolph-st/) | 0.23 mi W | Alteration or repair | Spr 2019 CBRC: construction of new cmu wall along basement vault - all work on private property. Relocated fire pump included on permit #101081154. (Occupancy B / construction type iv) certified corrections subject to field inspections & audit | $25,000 | [101085473](https://nearbypermits.com/chicago/permit/101085473/) |
| Sep 8, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Alteration or repair | Self cert 2019 CBRC: revision to permit 101081177 to include wall demo for office space expansion. No change to existing use. 1A construction. B-business demo only | $11,000 | [101086436](https://nearbypermits.com/chicago/permit/101086436/) |
| Sep 4, 2026 | [30 S Wacker Dr](https://nearbypermits.com/chicago/address/30-s-wacker-dr/) | 0.23 mi S | Alteration or repair | Self-cert 2019 CBRC: interior alterations of existing office space, suites 3600 and 3610. No exterior work. No work to egress system. (Occupancy group b-business; construction type 1a) | $1,750,000 | [101087431](https://nearbypermits.com/chicago/permit/101087431/) |
| Sep 3, 2026 | [500 W Madison St](https://nearbypermits.com/chicago/address/500-w-madison-st/) | 0.23 mi SW | Fire systems | Fire alarm: repair existing system. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: no. Monitoring type: supervising station. Specific location: 36th floor suite 3650. | Not listed | [B200507310](https://nearbypermits.com/chicago/permit/B200507310/) |
| Jul 29, 2026 | [500 W Madison St](https://nearbypermits.com/chicago/address/500-w-madison-st/) | 0.23 mi SW | Fire systems | Fire alarm: repair existing system. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: no. Monitoring type: supervising station. Specific location: suite 1100 11th floor. | Not listed | [B200472842](https://nearbypermits.com/chicago/permit/B200472842/) |
| Sep 2, 2026 | [30 S Wacker Dr](https://nearbypermits.com/chicago/address/30-s-wacker-dr/) | 0.23 mi S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101084454. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 25th floor. | Not listed | [B200480333](https://nearbypermits.com/chicago/permit/B200480333/) |
| Aug 3, 2026 | [30 S Wacker Dr](https://nearbypermits.com/chicago/address/30-s-wacker-dr/) | 0.23 mi S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101077927. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: city fire alarm box connection. Specific location: 37th floor. | Not listed | [B200478799](https://nearbypermits.com/chicago/permit/B200478799/) |
| Sep 2, 2026 | [500 W Madison St](https://nearbypermits.com/chicago/address/500-w-madison-st/) | 0.23 mi SW | Elevator | Replacement of hoist cables on two(2) 4000lb capacity, 29-floor, 1000fpm, passenger elevators(m2,m3), pursuant to the scope of work submitted.(ev009858) | Not listed | [101088023](https://nearbypermits.com/chicago/permit/101088023/) |
| Aug 31, 2026 | [10 S Riverside Plz](https://nearbypermits.com/chicago/address/10-s-riverside-plz/) | 0.23 mi S | Elevator | Replace hoist ropes on eg passenger car d, 4000lbs capacity, 12 stops, subject to city of chicago dept. Of buildings elevator bureau inspection (ev005799). | Not listed | [101087729](https://nearbypermits.com/chicago/permit/101087729/) |
| Aug 31, 2026 | [10 S Riverside Plz](https://nearbypermits.com/chicago/address/10-s-riverside-plz/) | 0.23 mi S | Elevator | Replace hoist ropes on eg passenger elevator car B, 4000lbs capacity, 12 stops, subject to city of chicago dept. Of buildings elevator bureau inspection (ev005799). | Not listed | [101087725](https://nearbypermits.com/chicago/permit/101087725/) |
| Aug 31, 2026 | [200 N La Salle St](https://nearbypermits.com/chicago/address/200-n-la-salle-st/) | 0.25 mi E | Alteration or repair | Self-cert 2019 CBRC alterations to existing first floor tenant space within existing 30 story mixed use building. Alterations include: new equipment and fixtures, electrical, plumbing, and mechanical. No change in use. All signage under separate permit. (Base building main address 200 north lasalle  | $1,300,000 | [101087061](https://nearbypermits.com/chicago/permit/101087061/) |
| Aug 25, 2026 | [10 S Riverside Plz](https://nearbypermits.com/chicago/address/10-s-riverside-plz/) | 0.23 mi S | Alteration or repair | Self-cert 2019 CBRC: interior renovation and expansion of existing 22nd floor office space. Work to include selective demolition, new construction of non-structural partitions, ceilings, finishes, furniture equipment and associated MEP for open office areas, private offices, meeting rooms and single | $3,600,000 | [101086577](https://nearbypermits.com/chicago/permit/101086577/) |
| Aug 21, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Alteration or repair | Self cert 2019 CBRC: interior renovations of partial 20th floor office space to convert to building amenity space. Work to include demolition and construction of non-load bearing partitions, ceilings, lighting, and associated MEP updates. IA Construction, b-business occupancy. | $478,325 | [101087081](https://nearbypermits.com/chicago/permit/101087081/) |
| Aug 21, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Alteration or repair | Self cert 2019 CBRC: partial interior renovation of the 33rd floor elevator lobby and core toilet rooms. Work to include demolition and construction of ceilings, lighting, toilet room partitions, finishes and fixtures. No change in use IA construction, b-business occupancy. | $346,174 | [101087079](https://nearbypermits.com/chicago/permit/101087079/) |
| Aug 21, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Alteration or repair | Self cert 2019 CBRC: partial interior renovation of the 20th floor elevator lobby and core toilet rooms. Work to include demolition and construction of new corridor demising partitions, ceilings and lighting. Core toilet room work to include new ceilings, lighting, toilet room partitions, finishes a | $388,849 | [101087077](https://nearbypermits.com/chicago/permit/101087077/) |
| Aug 21, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Alteration or repair | Self cert 2019 CBRC: interior alterations to partial 20th floor office space. Work to include demolition of non-load bearing partitions, ceilings and lighting. New work to include demising space for two tenant office suites - suites 2000 & 2050. New non-load bearing partitions, ceilings, finishes, a | $1,414,966 | [101087075](https://nearbypermits.com/chicago/permit/101087075/) |
| Aug 21, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Alteration or repair | Self cert 2019 CBRC: interior renovation of 16th and 33rd floor office space. Work on the 16th floor to include full renovation of floor including the demolition and construction of non-load bearing partitions for private offices and conference rooms, new pantry, updates to restrooms, and associated | $1,188,678 | [101087074](https://nearbypermits.com/chicago/permit/101087074/) |
| Aug 21, 2026 | [550 W Randolph St](https://nearbypermits.com/chicago/address/550-w-randolph-st/) | 0.24 mi W | Sign | Face illuminated business id sign to state "sram" below parapet. 24'L X 7'-5"H | $5,000 | [101083739](https://nearbypermits.com/chicago/permit/101083739/) |
| Aug 19, 2026 | [10 S Riverside Plz](https://nearbypermits.com/chicago/address/10-s-riverside-plz/) | 0.23 mi S | Elevator | Replacement of hoist cables on one(1) 4000lb capacity, 22-floor, 500fpm, passenger elevator(#13), pursuant to the scope of work submitted.(ev005799) | Not listed | [101087191](https://nearbypermits.com/chicago/permit/101087191/) |
| Aug 19, 2026 | [10 S Riverside Plz](https://nearbypermits.com/chicago/address/10-s-riverside-plz/) | 0.23 mi S | Elevator | Replacement of hoist cables on one(1) 4000lb capacity, 12-floor, 500fpm, passenger elevator(c), pursuant to the scope of work submitted.(ev005799) | Not listed | [101087185](https://nearbypermits.com/chicago/permit/101087185/) |
| Aug 18, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Alteration or repair | Corrective action to remove single door and sidelight and replace with double door and sidelight as permitted on 101079014. Locations: 0 residential unit(s), 1 non-residential unit(s), 1 interior common areas, level 2 concourse. | $20,000 | [B200476489](https://nearbypermits.com/chicago/permit/B200476489/) |
| Aug 18, 2026 | [333 W Wolf Point Plz](https://nearbypermits.com/chicago/address/333-w-wolf-point-plz/) | 0.21 mi N | Alteration or repair | Self cert 2019 CBRC - interior alterations to existing 19th, 20th, and 21st floor shell office space. Structural peer review included for new interconnecting stair. No change to existing use. No work to egress system. (Occupancy group B - business; construction type 1a) | $750,000 | [101085470](https://nearbypermits.com/chicago/permit/101085470/) |
| Aug 12, 2026 | [200 N La Salle St](https://nearbypermits.com/chicago/address/200-n-la-salle-st/) | 0.25 mi E | Fire systems | Fire alarm: modification of existing system. Associated building permit:101070373. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: suite 520. | Not listed | [B200475286](https://nearbypermits.com/chicago/permit/B200475286/) |
| Aug 12, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Elevator | Water damage repair/replacement on one(1) 4500lb capacity, 39-floor, 1200fpm, passenger elevator(#20), pursuant to the scope of work submitted.(ev007117) | Not listed | [101087204](https://nearbypermits.com/chicago/permit/101087204/) |
| Aug 11, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Alteration or repair | Self-cert 2019 CBRC: interior renovations to 34th-floor office space as per plans. Work to include demolition and construction of non-load-bearing partitions, lighting, doors and hardware, mechanical, electrical, and plumbing. No structural work. No change in use. (Construction type: 1a; occupancy:  | $307,760 | [101086760](https://nearbypermits.com/chicago/permit/101086760/) |
| Aug 10, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Electrical | Low voltage/communication electrical work. Install security. Specific location: ste 3000. | $5,357 | [B200481568](https://nearbypermits.com/chicago/permit/B200481568/) |
| Jun 25, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Electrical | Low voltage/communication electrical work. Install security. Specific location: suite 2323. | $10,814 | [B200475853](https://nearbypermits.com/chicago/permit/B200475853/) |
| Aug 10, 2026 | [549 W Randolph St](https://nearbypermits.com/chicago/address/549-w-randolph-st/) | 0.23 mi W | Alteration or repair | Selfcert 2019 CBRC: interior buildout to existing 2nd and 3rd floor office space. Demo permit #101084586. (Business / IV construction type) | $770,000 | [101085961](https://nearbypermits.com/chicago/permit/101085961/) |
| Aug 4, 2026 | [333 W Wolf Point Plz](https://nearbypermits.com/chicago/address/333-w-wolf-point-plz/) | 0.21 mi N | Electrical | Low voltage/communication electrical work. Install other. Install other. Install other. Install other. Specific location: 23rd floor. | $100,000 | [B200480669](https://nearbypermits.com/chicago/permit/B200480669/) |
| Aug 4, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Alteration or repair | Self-cert 2019 CBRC - interior alterations of 7,340 sqft for existing business office along with a lighting upgrade for the corridor and elevator lobby on the 17th floor. Scope includes alterations to mechanical, electrical, and plumbing. (Occupancy group B; type IA construction). | $530,000 | [101085888](https://nearbypermits.com/chicago/permit/101085888/) |
| Jul 29, 2026 | [549 W Randolph St](https://nearbypermits.com/chicago/address/549-w-randolph-st/) | 0.23 mi W | Alteration or repair | Office buildout increasing the size of existing tenant space by 475 sf | $40,000 | [101081807](https://nearbypermits.com/chicago/permit/101081807/) |
| Jul 28, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Fire systems | Fire alarm: modification of existing system. Associated building permit:101079711. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: city fire alarm box connection. Specific location: 10th floor (suite 1000). | Not listed | [B200477652](https://nearbypermits.com/chicago/permit/B200477652/) |
| Jul 14, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Fire systems | Fire alarm: modification of existing system. Associated building permit:b200460792. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 13th floor, suite 1330. | Not listed | [B200476070](https://nearbypermits.com/chicago/permit/B200476070/) |
| Jun 3, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Fire systems | Fire alarm: modification of existing system. Associated building permit:101078325. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: city fire alarm box connection. Specific location: suite 1200. | Not listed | [B200468672](https://nearbypermits.com/chicago/permit/B200468672/) |
| Jul 24, 2026 | [549 W Randolph St](https://nearbypermits.com/chicago/address/549-w-randolph-st/) | 0.23 mi W | Alteration or repair | Selfcert 2019 CBRC: interior demolition only to existing 2nd and 3rd floor office & assembly spaces. No change to existing use. (Business, a2 & a3 / IV construction type) | $111,000 | [101084586](https://nearbypermits.com/chicago/permit/101084586/) |
| Jul 24, 2026 | [500 W Madison St](https://nearbypermits.com/chicago/address/500-w-madison-st/) | 0.23 mi SW | Alteration or repair | Sself cert 2019 CBRC: interior alterations to existing 30th floor restrooms as per plans. Work to include demolition, new ceilings, finishes, lighting, electrical and plumbing. No change in use. No structural work. (Construction type: 1a; occupancy: b-business) | $350,000 | [101082409](https://nearbypermits.com/chicago/permit/101082409/) |
| Jul 23, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 8/1/2026. End date: 8/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and m | Not listed | [B200479570](https://nearbypermits.com/chicago/permit/B200479570/) |
| Jun 23, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 7/1/2026. End date: 7/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and m | Not listed | [B200475819](https://nearbypermits.com/chicago/permit/B200475819/) |
| Jul 22, 2026 | [1 N Wacker Dr](https://nearbypermits.com/chicago/address/1-n-wacker-dr/) | 0.20 mi S | Alteration or repair | Self cert 2019 CBRC: int minor renovation to existing office space to create a new suite approx. 937 SF. Of renovation | $200,000 | [101085738](https://nearbypermits.com/chicago/permit/101085738/) |
| Jul 20, 2026 | [1 N Wacker Dr](https://nearbypermits.com/chicago/address/1-n-wacker-dr/) | 0.20 mi S | Alteration or repair | .Scope: nonstructural interior alteration ceiling, lighting, electrical and ventilation work throughout suite as per plans..locations: 0 residential unit(s), 1 non-residential unit(s), 24th floor, office suite 2405. | $100,000 | [B200476996](https://nearbypermits.com/chicago/permit/B200476996/) |
| Jul 16, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | New building | Permit expires on 09/16/2026 erection starts: 8/3/2026, erection ends: 8/10/2026. Self cert CBC 2019 - one - 50ft x 66ft assembly tent and 2 - 20ft x 50ft reception tents for the estera wedding event on aug 8, 2026. Setup aug 3 and takedown aug 10, 2026. Blue peak tents. | $12,000 | [101085951](https://nearbypermits.com/chicago/permit/101085951/) |
| Jul 8, 2026 | [550 W Randolph St](https://nearbypermits.com/chicago/address/550-w-randolph-st/) | 0.24 mi W | Alteration or repair | In-kind replacement of exterior windows and doors in existing openings. Replacement windows: 154; replacement skylights: 0; replacement doors: 0. Affects: 0 residential unit(s), 6 non-residential unit(s), location: exterior windows of building. | $20,000 | [B200472029](https://nearbypermits.com/chicago/permit/B200472029/) |
| Jul 8, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Alteration or repair | Tuckpointing and unit masonry repair / replacement: 3400 SQ. FT., Lintel qty. 0, MAX. Length 0. Location: exterior facade. | $200,000 | [B200468631](https://nearbypermits.com/chicago/permit/B200468631/) |
| Jul 8, 2026 | [500 W Madison St](https://nearbypermits.com/chicago/address/500-w-madison-st/) | 0.23 mi SW | Elevator | Water damage repairs/replacement on one(1) 4000lb capacity, 29-floor, 550fpm, passenger elevator(m8), pursuant to the scope of work submitted.(ev009858) | Not listed | [101085753](https://nearbypermits.com/chicago/permit/101085753/) |
| Jul 6, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Alteration or repair | Selfcert 2019 CBRC: interior alterations to existing 16th floor office space - suite 1600. No change to existing use. Business / 1a | $75,000 | [101084700](https://nearbypermits.com/chicago/permit/101084700/) |
| Jul 2, 2026 | [10 S Riverside Plz](https://nearbypermits.com/chicago/address/10-s-riverside-plz/) | 0.23 mi S | Plumbing | For permit 101082245: replacement plumbing contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200477127](https://nearbypermits.com/chicago/permit/B200477127/) |
| Jul 2, 2026 | [171 W Randolph St](https://nearbypermits.com/chicago/address/171-w-randolph-st/) | 0.21 mi E | Electrical | Electrical maintenance permit. Occupancy: institutional. Start date: 7/1/2026. End date: 7/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit  | Not listed | [B200476954](https://nearbypermits.com/chicago/permit/B200476954/) |
| Jun 3, 2026 | [171 W Randolph St](https://nearbypermits.com/chicago/address/171-w-randolph-st/) | 0.21 mi E | Electrical | Electrical maintenance permit. Occupancy: institutional. Start date: 6/1/2026. End date: 7/1/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit a | Not listed | [B200472617](https://nearbypermits.com/chicago/permit/B200472617/) |
| May 6, 2026 | [171 W Randolph St](https://nearbypermits.com/chicago/address/171-w-randolph-st/) | 0.21 mi E | Electrical | Electrical maintenance permit. Occupancy: institutional. Start date: 5/1/2026. End date: 5/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit  | Not listed | [B200468750](https://nearbypermits.com/chicago/permit/B200468750/) |
| Jul 2, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101080114. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 26th floor - suite 2650. | Not listed | [B200474738](https://nearbypermits.com/chicago/permit/B200474738/) |
| Jul 1, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Alteration or repair | Self-cert 2019 CBRC - tenant buildout of 5,097 sqft for business office on the 23rd floor, including alterations to plumbing, electrical, and mechanical (occupancy group B; type IA construction) | $99,575 | [101085234](https://nearbypermits.com/chicago/permit/101085234/) |
| Jun 29, 2026 | [180 W Washington St](https://nearbypermits.com/chicago/address/180-w-washington-st/) | 0.23 mi SE | Scaffold or sidewalk shed | Temporary scaffolding: qty: 1, max. Length: 40 FT., max. Height: 180 FT. Location: exterior facade. Permit expiration date: 365 days from permit issued date this permit is not valid without corresponding cdot public way permit. | Not listed | [B200476439](https://nearbypermits.com/chicago/permit/B200476439/) |
| Jun 29, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 7/1/2026. End date: 7/31/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and m | Not listed | [B200476317](https://nearbypermits.com/chicago/permit/B200476317/) |
| May 28, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 6/1/2026. End date: 7/1/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and ma | Not listed | [B200472159](https://nearbypermits.com/chicago/permit/B200472159/) |
| Jun 29, 2026 | [10 S Riverside Plz](https://nearbypermits.com/chicago/address/10-s-riverside-plz/) | 0.23 mi S | Alteration or repair | Self cert 2019 CBRC: interior alterations to existing 12th floor restrooms, elevator lobby, and common corridors. Scope also to include white-boxing of existing office space. No change to existing use. No change to existing use. (Business / 1a) | Not listed | [101082245](https://nearbypermits.com/chicago/permit/101082245/) |
| Jun 25, 2026 | [500 W Madison St](https://nearbypermits.com/chicago/address/500-w-madison-st/) | 0.23 mi SW | Alteration or repair | Self cert 2019 CBRC: interior alterations to existing office suite 3650. Work to include demo, new partitions, mechanical, electrical and plumbing as plans. 1A construction. B-business | $750,000 | [101084739](https://nearbypermits.com/chicago/permit/101084739/) |
| Jun 24, 2026 | [30 S Wacker Dr](https://nearbypermits.com/chicago/address/30-s-wacker-dr/) | 0.23 mi S | Alteration or repair | Self cert 2019 CBRC: interior alteration for arrive logistics on the 25th floor. Work includes: interior walls, finishes, millwork, plumbing, mechanical, and electrical. No structural work. No change in use. B-business and construction type 1a | $1,451,746 | [101084454](https://nearbypermits.com/chicago/permit/101084454/) |
| Jun 22, 2026 | [313 W Wolf Point Plz](https://nearbypermits.com/chicago/address/313-w-wolf-point-plz/) | 0.21 mi N | Elevator | Hoist cable replacemenmt on one(1) 4000lb capacity, 61-floor, 1200fpm, passenger elevator(#2), pursuant to the scope of work submitted.(100821363) | Not listed | [101084849](https://nearbypermits.com/chicago/permit/101084849/) |
| Jun 18, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | New building | Self-cert 2019 CBC: level 1 alteration on floors 1 and 2 of a currently occupied 26 story fully sptinkered office building, including replacement of finishes, fixtures, and mechanical equipment within the interior and limited repaid/replace of exterior storefronts. No plumbing modifications, no stru | $1,500,000 | [101079014](https://nearbypermits.com/chicago/permit/101079014/) |
| Jun 17, 2026 | [1 N Wacker Dr](https://nearbypermits.com/chicago/address/1-n-wacker-dr/) | 0.20 mi S | Electrical | Low voltage/communication electrical work. Alter existing other. Specific location: twelve. | $100,000 | [B200472951](https://nearbypermits.com/chicago/permit/B200472951/) |
| Jun 11, 2026 | [1 N Wacker Dr](https://nearbypermits.com/chicago/address/1-n-wacker-dr/) | 0.20 mi S | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 7th, 14th and 15th floors. | $291,000 | [B200473490](https://nearbypermits.com/chicago/permit/B200473490/) |
| Jun 11, 2026 | [1 N Wacker Dr](https://nearbypermits.com/chicago/address/1-n-wacker-dr/) | 0.20 mi S | Electrical | Low voltage/communication electrical work. Install security. Specific location: 7th, 14th, and 15th floor. | $85,000 | [B200473037](https://nearbypermits.com/chicago/permit/B200473037/) |
| Jun 16, 2026 | [1 N Wacker Dr](https://nearbypermits.com/chicago/address/1-n-wacker-dr/) | 0.20 mi S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101079303. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 19th floor. | Not listed | [B200467456](https://nearbypermits.com/chicago/permit/B200467456/) |
| May 18, 2026 | [1 N Wacker Dr](https://nearbypermits.com/chicago/address/1-n-wacker-dr/) | 0.20 mi S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101079303. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 19th floor. | Not listed | [B200467452](https://nearbypermits.com/chicago/permit/B200467452/) |
| May 12, 2026 | [1 N Wacker Dr](https://nearbypermits.com/chicago/address/1-n-wacker-dr/) | 0.20 mi S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101077961. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: none (exempt). Specific location: floor 4. | Not listed | [B200466367](https://nearbypermits.com/chicago/permit/B200466367/) |
| Jun 15, 2026 | [500 W Madison St](https://nearbypermits.com/chicago/address/500-w-madison-st/) | 0.23 mi SW | Plumbing | For permit 101073496: replacement plumbing contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200474798](https://nearbypermits.com/chicago/permit/B200474798/) |
| Jun 15, 2026 | [10 S Riverside Plz](https://nearbypermits.com/chicago/address/10-s-riverside-plz/) | 0.23 mi S | Alteration or repair | Self-cert 2019 CBRC: interior alterations to existing 12th floor office space. Work to include demo, new partitions, electrical, plumbing, and mechanical as per plans. Occupancy b/ construction type 1a. | $6,000,000 | [101084344](https://nearbypermits.com/chicago/permit/101084344/) |
| Jun 11, 2026 | [30 S Wacker Dr](https://nearbypermits.com/chicago/address/30-s-wacker-dr/) | 0.23 mi S | Electrical | Line voltage electrical work. Add 6 circuits to existing 120 amp service disconnecting means. Receptacle outlets: 20. Lighting outlets: 0. Specific location: 25th floor. | $15,952 | [B200473096](https://nearbypermits.com/chicago/permit/B200473096/) |
| Jun 3, 2026 | [10 S Wacker Dr](https://nearbypermits.com/chicago/address/10-s-wacker-dr/) | 0.21 mi S | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 25th floor. | $22,325 | [B200473090](https://nearbypermits.com/chicago/permit/B200473090/) |
| Jun 3, 2026 | [333 W Wolf Point Plz](https://nearbypermits.com/chicago/address/333-w-wolf-point-plz/) | 0.21 mi N | Fire systems | Fire alarm: modification of existing system. Associated building permit:101075342. Affects: 0 dwelling units; 1 non-residential units. High-rise building: no. Voice communication: no. Special locking: yes. Monitoring type: none (exempt). Specific location: off of elevator bank. | Not listed | [B200469317](https://nearbypermits.com/chicago/permit/B200469317/) |
| May 28, 2026 | [333 W Wolf Point Plz](https://nearbypermits.com/chicago/address/333-w-wolf-point-plz/) | 0.21 mi N | Fire systems | Fire alarm: modification of existing system. Associated building permit:101080622. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 23rd floor. | Not listed | [B200470155](https://nearbypermits.com/chicago/permit/B200470155/) |
| Jun 3, 2026 | [313 W Wolf Point Plz](https://nearbypermits.com/chicago/address/313-w-wolf-point-plz/) | 0.21 mi N | Elevator | Replacement of hoist cables on one(1) 4000lb capacity, 61-floor, 1200fpm, passenger elevator(#2), pursuant to the scope of work submitted.(100821363) | Not listed | [101083983](https://nearbypermits.com/chicago/permit/101083983/) |
| Jun 2, 2026 | [333 W Wolf Point Plz](https://nearbypermits.com/chicago/address/333-w-wolf-point-plz/) | 0.21 mi N | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 23rd floor. | $176,000 | [B200472761](https://nearbypermits.com/chicago/permit/B200472761/) |
| May 28, 2026 | [333 W Wolf Point Plz](https://nearbypermits.com/chicago/address/333-w-wolf-point-plz/) | 0.21 mi N | Electrical | Low voltage/communication electrical work. Install other. Specific location: floor 23. | $456,633 | [B200472275](https://nearbypermits.com/chicago/permit/B200472275/) |
| May 13, 2026 | [333 W Wolf Point Plz](https://nearbypermits.com/chicago/address/333-w-wolf-point-plz/) | 0.21 mi N | Electrical | Low voltage/communication electrical work. Install security. Specific location: 23rd floor. | $20,000 | [B200470263](https://nearbypermits.com/chicago/permit/B200470263/) |
| Jun 1, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101078458. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 35th floor. | Not listed | [B200467604](https://nearbypermits.com/chicago/permit/B200467604/) |
| May 28, 2026 | [1 N Wacker Dr](https://nearbypermits.com/chicago/address/1-n-wacker-dr/) | 0.20 mi S | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 218. Lighting outlets: 0. Specific location: 7th floor. | $32,040 | [B200471769](https://nearbypermits.com/chicago/permit/B200471769/) |
| May 12, 2026 | [1 N Wacker Dr](https://nearbypermits.com/chicago/address/1-n-wacker-dr/) | 0.20 mi S | Electrical | Line voltage electrical work. Repair or alter devices on existing circuits. Receptacle outlets: 600. Lighting outlets: 0. Specific location: 14th floor. | $58,600 | [B200469692](https://nearbypermits.com/chicago/permit/B200469692/) |
| May 28, 2026 | [549 W Randolph St](https://nearbypermits.com/chicago/address/549-w-randolph-st/) | 0.23 mi W | Alteration or repair | Spr 2019 CBRC: replacement/relocation of existing fire pump at lower level office building. Pump to be relocated from existing vaulted sidewalk to interior of the building. (Occupancy B / construction type iv) | $70,000 | [101081154](https://nearbypermits.com/chicago/permit/101081154/) |
| May 27, 2026 | [180 W Washington St](https://nearbypermits.com/chicago/address/180-w-washington-st/) | 0.23 mi SE | Elevator | Software upgrade to comply with city of chicago 2017 phase II mandate on one(1) 2500lb capacity, 13-floor, 450fpm, passenger elevator(#1 north), pursuant to the scope of work submitted. | $10,832 | [101084020](https://nearbypermits.com/chicago/permit/101084020/) |
| May 22, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Electrical | Electrical maintenance permit. Occupancy: business. Start date: 6/1/2026. End date: 7/1/2026. All work under this permit must be performed by employees of the listed electrical contractor. The electrical contractor must maintain complete written records of all work performed under this permit and ma | Not listed | [B200471790](https://nearbypermits.com/chicago/permit/B200471790/) |
| May 22, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Alteration or repair | Spr 2019 CBRC: level 2 alteration to existing common space on floor 2 of a currently occupied 26 story fully sprinklered office building, including new partitions, finishes, fixtures, mechanical equipment, plumbing modifications, and structural modifications. No change of occupancy. (Occupancy group | $2,250,000 | [101077301](https://nearbypermits.com/chicago/permit/101077301/) |
| May 19, 2026 | [200 N La Salle St](https://nearbypermits.com/chicago/address/200-n-la-salle-st/) | 0.25 mi E | Fire systems | Fire alarm: modification of existing system. Associated building permit:101082592. Affects: 0 dwelling units; 0 non-residential units. High-rise building: yes. Voice communication: no. Special locking: no. Monitoring type: supervising station. Specific location: suite 600. | Not listed | [B200469685](https://nearbypermits.com/chicago/permit/B200469685/) |
| May 18, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: 23rd floor. | $5,000 | [B200471026](https://nearbypermits.com/chicago/permit/B200471026/) |
| May 18, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Sign | 9 Sq/ft non-illuminated wall sign; n/w elevation; chloe | $1,800 | [101083038](https://nearbypermits.com/chicago/permit/101083038/) |
| May 18, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Sign | 16 Sq/ft illuminated wall sign; north elevation; chloe | $3,500 | [101083035](https://nearbypermits.com/chicago/permit/101083035/) |
| May 18, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Sign | 41 Sq/ft illuminated wall sign; west elevation; chloe | $4,000 | [101083032](https://nearbypermits.com/chicago/permit/101083032/) |
| May 16, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: suite 1350. | $10,000 | [B200470727](https://nearbypermits.com/chicago/permit/B200470727/) |
| May 14, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: suite 2600. | $27,250 | [B200470629](https://nearbypermits.com/chicago/permit/B200470629/) |
| May 13, 2026 | [1 S Wacker Dr](https://nearbypermits.com/chicago/address/1-s-wacker-dr/) | 0.20 mi S | Electrical | Low voltage/communication electrical work. Install security. Specific location: ste 2600. | $5,400 | [B200470077](https://nearbypermits.com/chicago/permit/B200470077/) |
| May 13, 2026 | [10 S Wacker Dr](https://nearbypermits.com/chicago/address/10-s-wacker-dr/) | 0.21 mi S | Electrical | For permit 101080406: replacement general contractor. Replacement electrical contractor. Replacement plumbing contractor. Replacement other contractor. New contractor(s) listed under "other applicants and contractors" on permit certificate. | Not listed | [B200470049](https://nearbypermits.com/chicago/permit/B200470049/) |
| May 13, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Fire systems | Fire alarm: repair existing system. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: no. Special locking: yes. Monitoring type: supervising station. Specific location: 13th floor. | Not listed | [B200468547](https://nearbypermits.com/chicago/permit/B200468547/) |
| May 12, 2026 | [200 N La Salle St](https://nearbypermits.com/chicago/address/200-n-la-salle-st/) | 0.25 mi E | Electrical | Low voltage/communication electrical work. Install data/video. Specific location: suite 2700. | $28,814 | [B200469759](https://nearbypermits.com/chicago/permit/B200469759/) |
| May 12, 2026 | [2 N Riverside Plz](https://nearbypermits.com/chicago/address/2-n-riverside-plz/) | 0.21 mi SW | Alteration or repair | Self-cert 2019 CBC: limited nonstructural alterations to existing storefront and facades on ground floor and level 1 of existing 26 story fully sprinklered mixed use building. No plumbing modifications or change of occupancy. No interior scope. (Occupancy groups B and m, type 1a construction.) | $800,000 | [101076011](https://nearbypermits.com/chicago/permit/101076011/) |
| May 8, 2026 | [30 S Wacker Dr](https://nearbypermits.com/chicago/address/30-s-wacker-dr/) | 0.23 mi S | Fire systems | Fire alarm: modification of existing system. Associated building permit:101077927. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: no. Monitoring type: supervising station. Specific location: 12th floor. | Not listed | [B200467756](https://nearbypermits.com/chicago/permit/B200467756/) |
| May 6, 2026 | [150 N Clinton St](https://nearbypermits.com/chicago/address/150-n-clinton-st/) | 0.22 mi W | Elevator | Modernization of two(2) ewgt, 3000lb capacity, 7-floor, 2500fpm, passenger elevators(#3-#4), and one(1) 4000lb capacity, 7-floor, 200fpm, freight elevator(#5), pursuant to the scope of work submitted.(ev001206) | $1,220,860 | [101083163](https://nearbypermits.com/chicago/permit/101083163/) |
| May 6, 2026 | [1 N Franklin St](https://nearbypermits.com/chicago/address/1-n-franklin-st/) | 0.22 mi SE | Alteration or repair | Self cert 2019 CBRC: interior alterations to existing office suite 2600. Work to include demo, new partitions, mechanical, electrical and plumbing as per plans. 1A construction. B-business | $114,369 | [101081177](https://nearbypermits.com/chicago/permit/101081177/) |
| May 5, 2026 | [500 W Madison St](https://nearbypermits.com/chicago/address/500-w-madison-st/) | 0.23 mi SW | Electrical | Low voltage/communication electrical work. Install security. Specific location: flr 3. | $12,057 | [B200468857](https://nearbypermits.com/chicago/permit/B200468857/) |
| May 5, 2026 | [303 W Madison St](https://nearbypermits.com/chicago/address/303-w-madison-st/) | 0.22 mi SE | Fire systems | Fire alarm: modification of existing system. Associated building permit:101079127. Affects: 0 dwelling units; 1 non-residential units. High-rise building: yes. Voice communication: yes. Special locking: yes. Monitoring type: supervising station. Specific location: 19th floor suite 1925. | Not listed | [B200466681](https://nearbypermits.com/chicago/permit/B200466681/) |

## More on this street

Other addresses on N Wacker Dr with permits, nearest house number first:

- [155 N Wacker Dr](https://nearbypermits.com/chicago/address/155-n-wacker-dr/): newest permit Aug 1, 2026
- [150 N Wacker Dr](https://nearbypermits.com/chicago/address/150-n-wacker-dr/): newest permit Oct 2, 2026
- [180 N Wacker Dr](https://nearbypermits.com/chicago/address/180-n-wacker-dr/): newest permit Apr 14, 2026
- [190 N Wacker Dr](https://nearbypermits.com/chicago/address/190-n-wacker-dr/): newest permit Oct 23, 2025
- [191 N Wacker Dr](https://nearbypermits.com/chicago/address/191-n-wacker-dr/): newest permit Sep 21, 2026
- [123 N Wacker Dr](https://nearbypermits.com/chicago/address/123-n-wacker-dr/): newest permit Oct 5, 2026
- [120 N Wacker Dr](https://nearbypermits.com/chicago/address/120-n-wacker-dr/): newest permit Dec 3, 2024
- [110 N Wacker Dr](https://nearbypermits.com/chicago/address/110-n-wacker-dr/): newest permit Sep 21, 2026
- [101 N Wacker Dr](https://nearbypermits.com/chicago/address/101-n-wacker-dr/): newest permit Sep 23, 2026
- [29 N Wacker Dr](https://nearbypermits.com/chicago/address/29-n-wacker-dr/): newest permit Nov 24, 2025

---
Source: Chicago Department of Buildings permit data (https://data.cityofchicago.org/d/ydr8-5enu). Checked 2026-10-06 23:50 UTC. Nearby Permits, https://nearbypermits.com. JSON API and MCP server: https://nearbypermits.com/developers/

This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.

Map, all 8 permits at this address and 305 nearby: https://nearbypermits.com/chicago/address/160-n-wacker-dr/