New Orleans Department of Safety and Permits permit 24-02853-VCGEN: issued Feb 2, 2024 for alteration or repair work at 1041 Bourbon St. Replace a broken window pane. Repair small cracks in exterior stucco. ALL CRACKS MUST BE REPAIRED USING VCC APPROVED STUCCO MIX Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: • no greater than 1:12 part Portland Cement, to • 3 parts lime, and • 9 parts sand, • 6 lbs./cubic yard hair or fiber, and • enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: • No more than 1 Part Portland cement, • 3 Parts Lime, • 9 Parts Sand, • Enough water to form a workable mix. Prepackaged mixes are not permitted. Lath of any kind is not allowed. all paint to match existing Permit extended 6 months 12/17/24 rdbourgogne.

- Permit number: 24-02853-VCGEN
- Issued: Feb 2, 2024
- Type of work: Alteration or repair (city: VCC General Work, Business Use)
- Status: Issued (city: Permit Issued)
- Reported cost: Not listed
- ZIP code: 70116
- All permits at this address: https://nearbypermits.com/new-orleans/address/1041-bourbon-st/

---
Source: New Orleans Department of Safety and Permits permit data (https://data.nola.gov/d/72f9-bi28). Checked 2026-10-17 13:59 UTC. Nearby Permits, https://nearbypermits.com. JSON API and MCP server: https://nearbypermits.com/developers/

Every permit at 1041 Bourbon St: https://nearbypermits.com/new-orleans/address/1041-bourbon-st/