# Alteration or repair permit B2606262 at 1311 6th St NW, Washington

DC Department of Buildings permit B2606262: issued Jul 24, 2026 for alteration or repair work at 1311 6th St NW. Revision to approved permit b2502991 to change the sizing of a structural beam due to site conditions and update the footing details on the foundation plan to match site coniditions. Due to deterioration of the south brick (non-party) wall, a 25 foot section of that wall is now proposed to be built new rather than reused. No change to footprint, floor plans layout, or elevations. Original scope of b2502991: proposed level 03 addition to an existing 4 unit row building.

- Permit number: B2606262
- Issued: Jul 24, 2026
- Type of work: Alteration or repair (city: Construction, alteration and repair)
- Status: Issued (city: Permit issued)
- Reported cost: Not listed
- ZIP code: 20001
- All permits at this address: https://nearbypermits.com/washington-dc/address/1311-6th-st-nw/

---
Source: DC Department of Buildings permit data (https://opendata.dc.gov/datasets/7296e6392349498bb6ba6ba3db836644_18), CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Checked 2026-10-06 04:54 UTC. Nearby Permits, https://nearbypermits.com. JSON API and MCP server: https://nearbypermits.com/developers/

Every permit at 1311 6th St NW: https://nearbypermits.com/washington-dc/address/1311-6th-st-nw/