4800 E Falcon Dr
Building permits, Mesa, AZ
4800 E Falcon Dr, Mesa has 67 building permits on record. The most recent, opened Apr 23, 2026, is for other commercial: Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Hanger 104: 3704 SF Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire are…
All permits at this address
| Date | Type | Work | Cost |
|---|---|---|---|
| Other Commercial | Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Hanger 104: 3704 SF Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire… | – | |
| Commercial or Industrial Projects | Development of 26,515 SF pre-engineered metal hanger building with 7 bays. Type II-B construction, group S-1 occupancy. 2hr masonry wall separating (3) fire areas with 2hr east… | – | |
| Commercial or Industrial Projects | Installation of a new SRP meter and pedestal to power new Monument and Message Board Signs. Reference sign permit PMT20-12289. | – | |
| Sign Permit | City of Mesa project no. C09036MSG - Install one 18' OAH, double-face pylon with electronic message display for Falcon Field airport entrance, 62 sq. ft.. Sign is replacing an… | – | |
| Commercial or Industrial Projects | Expedite - new 33288 sf hangar building with spec offices known as hangar E (4453 E. Mallory cir.). Civil drawings are in permit number pmt20-02146. Pre engineered metal building… | – | |
| Sign Permit | Install one 24'-10" entrance pylon at the Northwest corner of Mckellips and Falcon Drive "FALCON FIELD Airport MESA, AZ" 61 SQ. FT. Monument is located at 32.23' from back of cub… | – | |
| Other Commercial | EXPEDITE - Grading & Drainage, Underground Utilities, Paving and storm drain improvements for 6 new buildings. Includes the landscape meter. Domestic Meters will be included on… | – | |
| Sign Permit | CIP# C09036CAP - Install four illuminated directional ground signs in private Falcon Drive islands: install one non-illumianted flat panel directional sign on existing light pole… | – | |
| Com (MSC) Annual Facilities Permit | Afp cip: remodel of existing pilot's lounge. Adding wall, cutting in new door. Relocating HVAC supply and return, electrical outlets. | – | |
| Svc (PSF) Miscellaneous Permits or Fees | Code modification: an appeal is hereby made to the building offical for a modification from section 311 of the ibc that requires that in teh referenced section of the ibc aircraft… | – | |
| Com (OTH) Electrical | Install new power and lighting circuit panel feed from panel "g2" install new power and lighting per 2005 nec and srp specifications. Also permit the existing waterline and… | – | |
| Com (OTH) Renovations or Remodels | Install new circuit from panel "p" to hanger p003. Tie in existing load, relocate switch & gfi. | – | |
| Com (OTH) Renovations or Remodels | Cip project - cp0257. Existing hangar demolition from fire damage and rehabilitation for use of existing structure. No new buildings or foundation work will be required, no change… | – | |
| Com (OTH) Electrical | Install new lighting and power outlets to existing separate curcuit | – | |
| Svc (PSF) Sign Permits | Install one (1) set of led halo-illuminated 2' tall reverse pan channel letters with logo to front elevation of building. "Logo (mesa az), falcon field". 69 SQ FT. One (1) sign id… | – | |
| Svc (PSF) Sign Permits | Install one (1) set of non-illuminated metallic copy finiish aluminium letters with logo to 3 FT tall monument wall (reference bld2014-06676-sheet a-026 for monument wall) 140 FT… | – | |
| Com (OTH) Deferred Fire Sprinklers | Cip project c10437 - deferred fire sprinklers. Ref bld2014-06676 | – | |
| Com (OTH) Electrical | Electrical permit to remove non permited electrical wiring and replace existing 400 metal halide fixtures with keyless sockets for use with 150w cfl city supplied lamps, to be… | – | |
| Com (OTH) Electrical | Hanger electrical panel replacements. Replacing 5 panels per attached plan. | – | |
| Com (OTH) Electrical | Add drywall & bring electrical to code in existing hangar, to be installed per 2005 nec. | – | |
| Com (OTH) Deferred Fire Alarms | Cip project c1437 - deferred fire alarm (ref bld2014-06676) | – | |
| Com (OTH) Remodeling with Addition | Cip project c10437 -- total interior renovation and exterior and site improvements to an existing general aviation airfield terminal originally constructed in 1971. Use to remain… | – | |
| Com (OTH) Electrical | Install one quad gfi receptacle in rear of hangar | – | |
| Com (OTH) Electrical | Install new 300 amp main breaker panel to replace existing 300 amp main lug panel remove 125 amp panel "restroom l" install new sub panel " restroom l" to panel "l1". | – | |
| Com (OTH) Renovations or Remodels | Convert partial 52 hangar occupancy to private offices with private restroom. Add new overead helicopter door to existing 52 occupancy mech, elec & plumbing. No fire sprinklers. | – | |
| Com (OTH) Electrical | Addition of electrical outlets & wood shelving. Work was done without a permit by prior tenant. | – | |
| Com (OTH) Electrical | Install 3 - 8' strip lights in hanger jj-1 | – | |
| Com (OTH) Electrical | Install lighting & convience outlets for city owned hangar building | – | |
| Com (OTH) Electrical | Correct code violations install new power and lighting | – | |
| Com (OTH) Renovations or Remodels | Demolition - remove non-permitted hangar modifications including wooden structure, bathroom, electrical modifications and plumbing. Return to original constructed condition… | – | |
| Com (OTH) Renovations or Remodels | Demolition - remove non-permitted electrical modifications in g-east storage room at falcon field airport. Bring storage unit back to original constructed condition. | – | |
| Com (OTH) Renovations or Remodels | Demolition - remove non-permited hangar modifications including wooden structure, bathroom, electrical modifications and plumbing. Return to original constructed condition… | – | |
| Com (OTH) Electrical | Replace electric panel and rework gfi | – | |
| Com (OTH) Electrical | Correct code violations and install new power & lighting. Approved per steve hether | – | |
| Com (OTH) Electrical | Install new power and lighting. | – | |
| Com (OTH) Electrical | Install new power and lighting , install new led fixture to existing lighting circuit for test for falcon field. This permit also includes existing waterline for swamp cooler and… | – | |
| Com (OTH) Non Structural | Install shelving ref main permit #bld2013-02385. | – | |
| Com (OTH) Non Structural | Remove mezzanine decking, modify office to meet code requirements (gg9)ref permit #bld2013-02386. Install pallet rack shelving (gg) | – | |
| Com (OTH) Electrical | Install (2) 4' t-8 strip lights at center ceiling area of hanger ff1 | – | |
| Com (OTH) Electrical | Correct code violations install new power outlets. Install per 2005 nec & srp standard details. | – | |
| Com (OTH) Electrical | Correct code violations install new power & lighting. Install per 2005 nec & srp standard details.location rr # 7 | – | |
| Com (OTH) Electrical | Correct code violations install new power outlets. Install per 2005 nec & srp standard details. | – | |
| Com (OTH) Electrical | Return house electrical to original condition. Install new 20 amp 120 volt circuit for new lighting and power | – | |
| Com (OTH) Electrical | Correct code viloations. Install new power and lighting | – | |
| Com (OTH) Electrical | Permit of existing electrical mod that were never permitted. | – | |
| Com (OTH) Electrical | Permit of existing electrical mods that were never permitted | – | |
| Com (OTH) Electrical | Permit existing outlets | – | |
| Com (OTH) Electrical | Permit existing light and outlet. Payment for this permit paid under bld2013-0044 per steve hether. | – | |
| Com (OTH) Electrical | Permit existing light and outlets | – | |
| Com (OTH) Electrical | Pbi - add 20 amp / 115 service to hanger m12 at falcon field | – | |
| Com (OTH) Electrical | B4, ii-n electrical work. All work per article 513 of 2005 nec. All fees paid under mother permit. Ref: bld2013-00099. | – | |
| Com (OTH) Electrical | B4, ii-n electrical work. All work per article 513 of 2005 nec. | – | |
| Com (OTH) Renovations or Remodels | Modify city hangar m-7. Add convenience outlets, add lighting, add water for evap cooler | – | |
| Com (MSC) Demolition Accessory Structure | Demo permit to remove wooden 2-story structure constructed without building permit. Remove all electrical modifications performed without permits. Return hangar to original… | – | |
| Com (OTH) Renovations or Remodels | Hangers z12 & ze. Install flourescent lights. Replace incandescent-hangar ze pre approved by airport manager. Frame sheet rock flight room. Work completed with out a permit | – | |
| Com (OTH) Renovations or Remodels | Hangar j fire damage repair shoring per fire damage assessment prepared by premier engineering corporation. | – | |
| Svc (PSF) Miscellaneous Permits or Fees | PERMIT TO WORK ON 8-23-2012 FROM 7PM TO 9 PM CONTACT: JEFF HAILY 602-309-9184 (FISHEL CO) If the Building Safety Director should determine that the public health and safety will… | – | |
| Com (OTH) Electrical | 2 Flourecent light fixtures: stipulations: 1. Minimum wiresize appropriate for ciruit 2. Breaker size appropriate for wire size 3. Wiring method for either fmc or fmt maximum… | – | |
| Com (OTH) Renovations or Remodels | Remodel of hanger space to include flight planning room & electrical work. 178 Sqft office in existing b3 storage hangar. No storage on deck. 60 Amp subpanel 240 circuit 120… | – | |
| Com (OTH) Renovations or Remodels | Pbi - (see case notes) 152 sqft accessory use (storge) s-2 occ. IIB Const. Apply intumescent fire retardant coating on existing exposed wood framing. Existing exposed electrical… | – | |
| Com (OTH) Electrical | Pbi - add (4) 8' fluorescent lights and (5) duplex outlets. Outlets to have gfci protection. | – | |
| Com (OTH) Plumbing | Revised as of 12-5-11: they are doing a new 2" landscape meter and service instead of the 1" wo#3218. Installation of 1" landscape service & meter to service landscaping for… | – | |
| Com (OTH) Non Structural | Appeal made to the building official for a code modification from, or interpretation of section 306.2 of the international building code which requires aircraft fabrication oand… | – | |
| Com (OTH) Renovations or Remodels | Cip #07-041-001 for reconfiguration of taxiway " B " and installation of runway guard lights at falcon field airport. To include: demo., grading/drainage, paving, barricades… | – | |
| Com (OTH) Non Structural | Com project #07-038-001.** install five (5) new motorized & manual vehicle access control gates ( 7,8,9,11 & 12), area pole lighting w/ foundation, asphalt concrete access roads… | – | |
| Com (OTH) Non Structural | Install vehicle access control (phase 3) at 9 locations on falcon field to include structural, elect. Power/ lighting and communications. REF. City prj # 04-850-001, bsd work… | – | |
| Com (OTH) Non Structural | Work order # 4086 com project#01-496-001 falcon field echo ramp 24,500 sy expansion.to include: demolition of pavement,piping, headwalls, riprap and elect. New work includes… | – |
Checked 2026-10-01 10:21 UTC against Mesa Development Services permit data. Markdown · JSON