Nearby Permits

C wing -suite conversion for c &d wing

Sign at 22 S Greene St, Baltimore

Baltimore Department of Housing and Community Development permit COM2022-01251: issued Aug 24, 2022 for sign work at 22 S Greene St. c wing -suite conversion for c &d wing; create a single c&d wing patient care suite; finishes, furniture, casework & equipment; all new finishes, furniture, casework & equipment; walls- new non- rated interior walls & doors; new 1 hr rated wall enclosure at clean storage room; new toilet rooms; ceiling-existing ceiling rehab, existing lighting to remain; mechanical new-rebalance terminal units air flow and verify heating water flow; provide new fin tube covers. plumbing new-provide new water closets and sinks in same locations, as indicated and specified; provide shower trim; provide new covers and signage to indicate medical gas system is not in use. electrical new-infusion spaces shall have mobile lighting by ummc; infusion spaces shall have new ceiling mounted fixture to achieve required levels; relocate or provide additional normal and emergency receptacles as indicated; circuit tracing of existing emergency circuits required by contractor; provide rough-in for ctsi nurse call design d wing - suite conversion for c &d wing; create a single c&d wing patient care suite; finishes, furniture, casework & equipment; all new finishes, furniture, casework & equipment; walls- new non- rated interior walls & doors; ceiling- new ceilings & lighting; mechanical new -rebalance existing air handling unit; provide new heating water coils and new ductwork and air devices downstream of coils; reinstall sections of supply, return and exhaust branch ductwork to accommodate new architectural layout; rebalance heating water; provide new isolation room exhaust and general exhaust fans; provide new air terminal unit for ad shaft supply duct; provide new ductwork and associated fire smoke damper for ad shaft supply; provide new piping above ent suite as needed to accommodate new ductwork and associated fire smoke damper. electrical new- infusion spaces shall have new ceiling mounted fixture to achieve required levels; provide additional normal and emergency receptacles as indicated; as per plans as per scope. separate permit required for sprinkler and fire alarm system.

Permit number
COM2022-01251
Issued
Type of work
Sign
Status
Issued
Reported cost
$3,500,000
ZIP code
21201 (from the permit's location)
City's category
2-07
City's status
Not listed
Source
Baltimore Department of Housing and Community Development permit data (this record)

Type of work and status are our own standard labels, so permits compare across cities. The city's wording is in the "City's category" and "City's status" rows. We show costs under $100 as not listed, because filers often enter $0 or $1 when the city doesn't require a cost.

All permits at 22 S Greene St, and what's permitted nearby

Baltimore Department of Housing and Community Development updated its data Oct 11, 2026. We checked it Oct 11, 22:24 UTC. See the city's official records (City of Baltimore, CC BY 3.0).