Nearby Permits

Remodel the first floor like require on the plan

Alteration or repair at 730 E Third St, Boston

Boston Inspectional Services Department permit SF1694155: issued Mar 13, 2025 for alteration or repair work at 730 E Third St. Remodel the first floor like require on the plan. • Full Kitchen remodel. • Full bathroom remodel. • Replace wood trims in the bedrooms, close one door in the hallway entrance. • Refinish the floors and paint the apartment. • Plumber Kitchen. • Kitchen Remodeling. Provide all new stop valve to hot and cold water, supply line, water hammer arrestor. Install new kitchen faucet, Disposal, • Dishwasher and refrigerator water line. • Eliminate gas stove. • Bathroom. • Provide Rough Plumbing and Finish installation to new Full Bathroom (Toilet, Vanity, Shower). Material: PVC and PEX. Provide Basic • Symmons Shower Control Chrome Finish. • Laundry. • Eliminate gas dryer. • Provide water hammer arrestor to washer machine faucet. • Electrical. • CLASS 320/400AMPS SERVICE UPGRADE; • Provide full house load calculation and initiate work request authorization for a new 400amps service with Eversource utility engineering. • Supply and install (at existing service location) one 400amps 120/240volts, single phase indoor rated main service disconnect. • Supply and install one 4 gang/400amp outdoor condo meter bank to serve units 1, 2, 3 and common public meter at exterior wall (near the gate) in alleyway. • Supply and install one 125amp rated electrical panel board to serve unit #1. • Re-feed existing electrical panels to units 2 and 3 with new 100amp sub-feeders and 100amp exterior main breakers to re-energize existing panel boards (panels to remain AS-IS at existing location). • Re-feed existing electrical public panel with new 60amp sub-feeder and 60amp exterior main breaker to re-energize existing panel board (panel to remain AS-IS at existing location). • Supply and install "WHOLE-HOUSE SPD" (Surge Protection Devices), one in each panel. • Supply and install two supplemental grounding electrodes 8 feet down into earth and connect to electrical system. • Supply and install one communication intersystem bonding bridge to outdoor meter socket for telecom bonding. • Supply and install main grounding conductor to water pipe (main grounding electrode). • This estimate DOES NOT include modification/relocation/troubleshooting or upgrade of existing branch circuits currently serving the building or common areas of the building (ALL TO REMAIN "AS-IS"). • Required upgrade/replacement or rewiring of 120/240volts, 3 prong branch circuit appliances (ranges, dryers, etc.), plug in or hardwired due to lack of a grounding conductor (IF ANY) are not included in this estimate. • Client to provided building square footage and all appliance's name plate to initiate required load calculation. • GC to build a soffit across basement ceiling to accommodate all feeder cables from mechanical room to exterior equipment. • GC and client to provide all required 3/4" plywood mounting boards, excavation/trench and back fill as needed. • ALL required electrical equipment spaces and working clearances must be provided by GC and client, there shall be no foreign mechanicals or structures within the dedicated equipment and working spaces (measured from floor to ceiling), minimum required space to be 30 inches wide (or width of equipment) by 36 inches depth (from face of equipment), all measurements taken from floor to structural ceiling (beyond ceiling covering material). • Any relocation of existing obstruction(s) or foreign equipments must be provided by client/gc and others (not included in this estimate). • Existing underground service lateral is owned by Eversource utility company, any costs related to Eversource (if any), outside of the building, which may include digging, conduits, disconnect/reconnect/shut downs or upgrades of any related work or equipment at their side (building to transformer) ARE NOT included in this estimate. ALL Eversource costs (if any) are not included in this estimate and is to be paid by client directly to utility company. • Complete rewire of 1st floor units as following; • -smoke+carbon monoxide detectors (hardwired): • supply and install 120v. hardwired, interconnected with battery back-up smoke and carbon monoxide detectors to entire 1st fl. unit per code. • -FRONT HALLWAY: • Supply and install 100amp. sub-panel to be installed at end of hallway near kitchen entryway. • Supply and install one WHOLE HOUSE surge protector. • Install THREE (3) customer supplied wall sconces to be controlled by a 3way toggle dimmer switch loop. • Supply and install wall receptacle and plates to code. • Supply and install one LED closet light controlled by a single pole wall switch. • -BATHROOM: • Supply and install ONE (1) Panasonic fan/light to be controlled by one single pole toggle switch (exhaust ductwork by others). • Supply and install ONE (1) FIRE RATED 4" wafer 3000K LED can less white trim recess shower light to be controlled by fan switch. • Install ONE (1) customer supplied wall sconces to be controlled by a single pole toggle switch. • Supply and install ONE (1) 20amp AFCI/GFCI protected receptacle. • -LIVING ROOM: • Supply and install FIVE (5) FIRE RATED 4" wafer 3000K LED can less white trim recess light to be controlled by a 3way toggle dimmer switch loop. • Install ONE (1) customer supplied ceiling fan/light to be controlled by one single pole toggle switch. • Supply and install ONE (1) point coaxial cable next to fire place. • Supply and install ONE (1) HDMI cable above fire place. • Supply and install ONE (1) point of Ethernet Cat5 from modem point room to above fire place. • Supply and install one 120v. receptacle above fire place (TV supplied and mounted in place by others). • Supply and install wall receptacles and plates to code. • -DINING ROOM: • Install ONE (1) customer supplied pendant light fixture over dinning table to be controlled by a 3way toggle dimmer switch loop • Install switches and receptacles to code. • -KITCHEN (fully gutted ceiling and walls): • Supply and install THREE (3) FIRE RATED 4" wafer 3000K LED can less white trim recess light to be controlled by a 3way toggle dimmer switch loop. • Supply 6-3NMB 40amp/240volt dedicated GFCI circuit to customer supplied INDUCTION STOVE (mounted in place by others). • Supply (one each) dedicated 120volts/20amp AFCI/GFCI circuit to customer supplied; Fridge, dishwasher, garbage disposal and range hood (mounted/vented by others). • Supply and install two small appliances 120v/20amp AFCI/GFCI protected counter circuits/receptacles loop. • Install customer supplied 120v integrated LED under cabinet lights to be controlled by one single pole dimmer switch. • Install wall switches, receptacles and plates to code. • -LAUNDRY: • Supply and install ONE (1) 240v/30a/4prong GFCI protected dryer receptacle. • Supply and install ONE (1) 120v/20a/3prong AFCI/GFCI protected washer receptacle. • -PRIMARY BEDROOM: • Supply and install FOUR (4) FIRE RATED 4" wafer 3000K LED can less white trim recess light to be controlled by a single pole toggle dimmer switch. • Install ONE (1) customer supplied ceiling fan/light to be controlled by one toggle switch. • Supply and install ONE (1) point Coaxial cable. • Supply and install TWO (2) points Ethernet Cat5 from modem point to desk. • Supply and install one LED light in each closet to be controlled by a single pole wall switch. • Supply and install wall receptacles and plates to code. • -GUEST BEDROOM/OFFICE: • Supply and install ONE (1) FIRE RATED 4" wafer 3000K LED can less white trim recess light over desk to be controlled by a single pole toggle dimmer switch. • Install ONE (1) customer supplied ceiling fan/light to be controlled by one 3way toggle switch. • Supply and install ONE (1) point Coaxial cable. • Supply and install TWO (2) points Ethernet Cat5 from modem point to desk. • Supply and install wall receptacles and plates to code. • -HVAC (specs are required prior to rough wiring): • Wire ONE (1) customer supplied air handler located in basement. • Wire ONE (1) 240v/40amp max. circuit for customer supplied outdoor heat pump condenser unit. • Supply and install one NEMA-3 outdoor knife switch service disconnect. • ***ALL units electrical access panels must comply with a minimum of 30in. x 3ft. working space (in front of access panel) as per NEC Art.110.26 prior to wire hook-up. • ***ALL controls wiring supplied by others. • HVAC. • Job Description Provide and Install a or bosh heat pump system and all ductwork related in order to supply heating and cooling conditions to a single-family home. Ductwork: Sheet Metal, Flexible, Transitions, Boots, Insulation. Finishing; Line Set, Drain Line, Hangers, Gutters, Diffusers and Registers, Thermostats. - All HVAC labor and parts required for the job are included in this estimate. - We do provide a (1) year labor warranty. - All wire high and low voltage to be provided by certified electrician at owner's expenses. • Outdoor Condenser Outdoor condenser unit to be installed with test pressure and vacuum clean. Provide all necessary stock (line set, cover Pad) • Equipment AHRI # 214053824———————— B68-880 BOVD36HDN1M20 HEAT PUMP BOSCH CONNECTED 20SEER2 13.00EER2 9.5HSPF 3T SINGLE PHASE INVERTER DRIVEN 208/230V R410A Pn: 413219—————— L95 709 BVA-36WN1-M20 AIR HANDLER SINGLE PIECE BOSCH 3T ECM FACTORY INSTALLED TXV 8-733-952-440 Pn: 227333 • MANUAL J CALCULATION Manual J is the protocol used for determining the amount of heating and cooling that a home requires to keep its occupants warm in the heating months and cool and dry in the cooling months * Finishing materials (bathroom and kitchen - example: bath, tiles, cabinets, appliances, etc) are not included.

Permit number
SF1694155
Issued
Type of work
Alteration or repair
Status
Finished
Reported cost
$155,000
ZIP code
02127
City's category
Renovations - Interior NSC, Short Form Bldg Permit
City's status
Closed
Source
Boston Inspectional Services Department permit data (this record)

Type of work and status are our own standard labels, so permits compare across cities. The city's wording is in the "City's category" and "City's status" rows. We show costs under $100 as not listed, because filers often enter $0 or $1 when the city doesn't require a cost.

All permits at 730 E Third St, and what's permitted nearby

Boston Inspectional Services Department updated its data Oct 3, 2026. We checked it Oct 4, 12:19 UTC. Official data.

For agents and scripts: This page as Markdown · JSON