? System size: 10000w dc, 11500w ac
Electrical at 4660 Ricara Dr, Boulder
Boulder Planning and Development Services permit ELE2024-01001: issued Dec 9, 2024 for electrical work at 4660 Ricara Dr. ? System size: 10000w dc, 11500w ac ? Modules: (25) longi green energy technology co ltd: lr5-54habb-400m ? Inverters: (1) tesla: powerwall 3 1707000-xx-y ? Racking: snapnrack rlu; rl universal, speedseal track on comp to framing, see detail snr-dc-00436 ? Energy storage system: (1) tesla: powerwall 3 1707000-xx-y ? Rapid shutdown: (10) tesla mid circuit interrupter (mci) rooftop module level rapid shutdown device ? Animal deterrent system to be installed around.
- Permit number
- ELE2024-01001
- Issued
- Type of work
- Electrical
- Status
- Finished
- Reported cost
- $31,000
- ZIP code
- 80303
- City's category
- Electrical Permit, Electrical Permit
- City's status
- Letter of Completion
- Source
- Boulder Planning and Development Services permit data (this record)
Type of work and status are our own standard labels, so permits compare across cities. The city's wording is in the "City's category" and "City's status" rows. We show costs under $100 as not listed, because filers often enter $0 or $1 when the city doesn't require a cost.
All permits at 4660 Ricara Dr, and what's permitted nearby
Boulder Planning and Development Services updated its data Oct 7, 2026. We checked it Oct 8, 02:15 UTC. See the city's official records.
For agents and scripts: This page as Markdown · JSON