Nearby Permits

Touch Screen Boiler Controller

Mechanical (HVAC) at 3147 8th St, Boulder

Boulder Planning and Development Services permit MEC2026-01628: issued Sep 4, 2026 for mechanical (hvac) work at 3147 8th St. Touch Screen Boiler Controller: ? Express setup? Remote monitoring & diagnostics? Easy USB programmability? Cascade up to 4 units? Intuitive alert system? Simplified load pairing? Visible flame current data for troubleshooting· 95% AFUE· Built-in 4 zone pump or valve control in addition to the primary control. 5 pumps total. Replacing the need for external pump controls· PVC/CPVC/PPs approved ? venting up to 240ft (each side) on the VX 110· MFZ Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler. · Built-in CSA/UL approved LWCO and manual reset high limit. · Connect your IBC Indirect Water Tank directly to the boiler without a primary loop.· Turndown ratio of up to 6.5:1 means you have the power to heat your home in the coldest weather yet reduce short cycling when the weather is mild. · Built-in outdoor reset control of water temperature. · Reverse flow detection. ·· 5 Year limited manufacturer?s parts warranty. · Limited 15-year residential heat exchanger warranty. -All low-voltage wiring and control integration -Ball valves and boiler drains -Air separator and automatic air vent -Automatic fill valve and backflow preventer -Expansion tank (sized appropriately) -Condensate neutralizer and pump (if needed) -Exhaust and intake venting (PVC/CPVC or approved venting to code) -All required piping, fittings, supports, and installation materials -Full system start-up and commissioning Electrical Note: If electrical circuit modifications or additions are necessary, a licensed third-party electrician will be required. This work is not included and will be quoted separately if needed. Warranty: Manufacturer?s warranty on boiler + 1-year labor warranty on installation. Exclusions: Structural modifications or hazardous material remediation (e.g., asbestos) are not included and will be quoted separately if discovered. Note: If a sidearm (indirect water heater) is required for domestic hot water, it will be quoted as a separate line item. PLEASE NOTE: APPLICABLE ONLY TO SYSTEMS WITH FUEL BURNING APPLIANCES: All new plastic glued vents for fuel burning appliances must undergo pressure testing. To facilitate the inspection process, please provide photographic evidence of the pressure test directly to the assigned inspector on the day the rough mechanical inspection is scheduled. Approved tests: 10 ft water test, 5 PSI positive pressure, or Negative 5 psi air pressure test for 15 Minutes. Any electrical work required beyond a like-for-like replacement of equipment will require an electrical permit for inspection of the electrical scope.

Permit number
MEC2026-01628
Issued
Type of work
Mechanical (HVAC)
Status
Issued
Reported cost
$24,388
ZIP code
80304
City's category
Mechanical Permit, Mechanical HVAC/Solar
City's status
Issued
Source
Boulder Planning and Development Services permit data (this record)

Type of work and status are our own standard labels, so permits compare across cities. The city's wording is in the "City's category" and "City's status" rows. We show costs under $100 as not listed, because filers often enter $0 or $1 when the city doesn't require a cost.

All permits at 3147 8th St, and what's permitted nearby

Boulder Planning and Development Services updated its data Oct 6, 2026. We checked it Oct 6, 22:43 UTC. See the city's official records.

For agents and scripts: This page as Markdown · JSON