Only the electrical scope of work associated with the heat pump installation for the house is included on
Mechanical (HVAC) at 3065 24th St, Boulder
Boulder Planning and Development Services permit MEC2026-01715: issued Oct 5, 2026 for mechanical (hvac) work at 3065 24th St. Only the electrical scope of work associated with the heat pump installation for the house is included on this permit. Any additional electrical work will need to be permitted separately - more specifically the circuit for the induction stove will need to be permitted separately and is not approved on this permit. 1x Mitsubishi Air Handler - SVZ-AP30NL - Crawlspace 1x Mitsubishi Heat Module Unit - EH05-SVZ-M - 5kW heat strip (230V 30A) 1× Mitsubishi Controller Kit Unit - MHK2 - Wireless thermostat 1× Mitsubishi Outdoor Unit - MUZ-FX18NLHZ - Outside workshop 1× Mitsubishi Wall Mounted - MSZ-FX18NL - Workshop 1× Mitsubishi Outdoor Unit - SUZ-AK30NLHZ - ODU Main Home 1× Aprilaire Humidifier - RSP600M Humidifier in Crawlspace + MERV Filter Cabinet HVAC Scope: * Install one (1) Mitsubishi 18,000 BTU wall-mounted ductless indoor unit for dedicated zone heating and cooling AHRI 215712240 * Install one (1) Mitsubishi 30K BTU ducted air handler to serve existing ductwork and provide whole-home conditioned with 5 kW back up heat * Run and connect all required refrigerant lines, electrical wiring, and condensate drainage * Integrate both indoor systems for coordinated heating and cooling operation * Perform system startup, testing, and manufacturer-required commissioning procedures * Verify proper airflow, refrigerant charge, and system performance across all zones * Provide homeowner orientation on system operation and controls * Ensure installation meets all applicable mechanical codes and manufacturer specifications * Installation of humidifier on crawlspace system Electrical Scope: 1x 230V 30A Heat Pump Circuit 1x 230V 20A Heat Pump Circuit 1x 230V 30A 5kW Heat Strip Circuit PLEASE NOTE: APPLICABLE ONLY TO SYSTEMS WITH FUEL BURNING APPLIANCES: All new plastic glued vents for fuel burning appliances must undergo pressure testing. To facilitate the inspection process, please provide photographic evidence of the pressure test directly to the assigned inspector on the day the rough mechanical inspection is scheduled. Approved tests: 10 ft water test, 5 PSI positive pressure, or Negative 5 psi air pressure test for 15 Minutes.
- Permit number
- MEC2026-01715
- Issued
- Type of work
- Mechanical (HVAC)
- Status
- Issued
- Reported cost
- $30,551
- ZIP code
- 80304
- City's category
- Mechanical Permit, Mechanical with Electrical
- City's status
- Issued
- Source
- Boulder Planning and Development Services permit data (this record)
Type of work and status are our own standard labels, so permits compare across cities. The city's wording is in the "City's category" and "City's status" rows. We show costs under $100 as not listed, because filers often enter $0 or $1 when the city doesn't require a cost.
All permits at 3065 24th St, and what's permitted nearby
Boulder Planning and Development Services updated its data Oct 8, 2026. We checked it Oct 9, 07:44 UTC. See the city's official records.
For agents and scripts: This page as Markdown · JSON