8046 E Ray Rd, Mesa has 26 building permits on record. The most recent, opened Sep 8, 2026, is for fire systems: Remodel of existing 3,130 SF maintenance area. 1,330 to be partitioned off (non-structural) and used as accessory assembly conference room. 1,800 SF to remain maintenance area. Mod…
All permits at this address
| Date | Type | Work | Cost |
|---|---|---|---|
| Fire systems | Remodel of existing 3,130 SF maintenance area. 1,330 to be partitioned off (non-structural) and used as accessory assembly conference room. 1,800 SF to remain maintenance area… | – | |
| Alteration or repair | Tenant improvement of 1,650 SF of B occupancy office/work areas in existing 555,245 SF type VB construction, B and S-1 occupancy warehouse. Modification include install of… | – | |
| Alteration or repair | Removal of 6 aisles of existing racking 14,000 SF, adding automation of 7 existing dock doors and addition of dock levelers and accessories, electrical associated with the dock… | – | |
| Alteration or repair | Tenant improvement in existing 486,104 SF, type VB construction, S-1 occupancy. Install of (22) bays of pallet racking, in a 11,370 SF area. Special inspection req. - Anchors… | – | |
| Electrical | Revisions to the one line per the Dexcom Mesa Facility Electrical Equipment Mechanical Sequence Modification plan. Existing SES-B: update one-line for existing 1200A circuit… | – | |
| Other | Like for like reconstruction. Storm Damage Report COB23-00076. | – | |
| Fire systems | Removal of (6) aisles of existing racking - approximately 10,000 SF. Automation of (7) existing overhead dock doors and addition of dock levelers and accessories. Special… | – | |
| Alteration or repair | Installation of (2) new G-1 style shade canopies in existing landscape areas. 64 SF each. | – | |
| Alteration or repair | Add 2' high wrought-iron on existing masonry wall | – | |
| Plumbing | EXPEDITE - Installation of a 2-inch water line and 2" domestic water meter & backflow preventer | – | |
| Sign | Install 3 non-illuminated monuments for "DEXCOM" each 6' to copy and 14 sq. ft. all along Ray Road:Sign B.1 located at the Northern most entrance at 27' from back of curb to… | – | |
| Electrical | Electrical connections associated with future conveyor installation. Conveyors under separate permit. | – | |
| Sign | Install two set of LED illuminated pan channel letters "dexcom", each 160 sq. ft. installed at the Northeast and Southwest elevation of building. | – | |
| Fire systems | Interior alteration to NW side of existing 8,835 SF facility. Add electrical charging stations for forklift and handling equipment dry lead battery charging. Battery charger in… | – | |
| Alteration or repair | Replace existing fire pump controller with a new controller and power transfer switch. | – | |
| Alteration or repair | Install 360,600 s.f. of steel high-piled storage racking system in distribution warehouse for Class III, encapsulated electronics stored in cardboard boxes. Fire sprinkler system… | – | |
| Fence, wall or deck | SUPER EXPEDITE - Site Modifications - New gates, fencing, and/or site lighting in the following areas: 1. Truck entry - SE corner. 2. Visitor entry - NE corner. 3. Security fence… | – | |
| Addition | SUPER EXPEDITE - See PMT20-18310 for 110 SF Guard Shack, Visitor Center Entrance. Relocation of a fire hydrant, abandonment and relocation of a water easement, removal of 2 solid… | – | |
| Addition | Construct 6,245 SF masonry addition to the west side of an existing warehouse. Addition includes Hazmat Storage Room (H-3), receiving dock (S-1) and mechanical room (S-1). Civil… | – | |
| Alteration or repair | Revised and added scope to work to PMT20-15085. Changes and additions indicated by Delta 1 symbols. Revisions includes replacing open office area with computer assemblies and… | – | |
| Alteration or repair | SUPER EXPEDITE - Complete office improvements for 2 shell areas located in the NE and SE corners designated under Phase 1 Permit PMT20-13100. User specific areas and secondary… | – | |
| Fire systems | New 7,800 SF Central Utilities Plant Building Addition: 4,680 SF Outdoor Equipment Yard: 70,900 SF Equipment Platform (Internal to Existing Building). Deferred fire sprinklers and… | – | |
| Sign | Install 5 vehicle access gates across designated fire access lanes. Gates will be equipped with backup battery support, fire lane signage, optical sensors, and Knox boxes… | – | |
| New building | Pump Room HVAC PMT19-11482 Mechanical for the Shell building | – | |
| Sign | Install one internally illuminated monument sign with routed out faces, 6' to copy, "L LANDING 202" 13 SQ. FT. Sign is located at 27' from back of curb to leading edge of sign and… | – | |
| Fire systems | New concrete tilt panel shell building. No certificate of occupancy. 486,104 s.f., occupancy classification S-1, construction type VB (unlimited area). Civil plans show 8-inch… | – |