8223 E Pecos Rd, Mesa has 22 building permits on record. The most recent, opened Feb 18, 2026, is for sign: Installation of one non-illuminated FCO letters stud mounted flush to front of building. Metso 15 sq. ft. existing sign on east elevation is 15 sq. ft.
All permits at this address
| Date | Type | Work | Cost |
|---|---|---|---|
| Sign | Installation of one non-illuminated FCO letters stud mounted flush to front of building. Metso 15 sq. ft. existing sign on east elevation is 15 sq. ft. | – | |
| Solar | Electrical Service Modification for Metso rooftop solar. Modify existing Electrical service to add ne Bi-directional meter, with existing 400amp disconnect. for new rooftop… | – | |
| Roofing | Development expansion of 20,607 SF, type III-B construction, groups S-1 and F-1 occupancies to an existing pre-engineered metal building. Development of a new PEMB shipping &… | – | |
| Grading | Building additions with associated paving, grading, and waterline improvements. One new 2" domestic water meter. Landscape irrigation to use existing 1.5" LS water meter. | – | |
| Fire systems | Construct pre-engineered metal 7,047 SF training center building and renovate existing masonry building for new offices and various interior remodels. Type V-B construction with… | – | |
| Fence, wall or deck | (4) 560sf Pre-engineered building structures, used for storing excess material. | – | |
| Other | potholing for design discovery of utilities | – | |
| Sign | Manufacture and install three (3) sets of non-Illuminated pan channel letters at the North, East and West elevation of building "Metso:Outotec" each 20 sq. ft. | – | |
| Fire systems | Linear heat detection for deluge sprinkler system releasing. Also, monitor new sprinkler system water flow, tamper and releasing solenoid and tie into an exiting fire alarm system… | – | |
| Alteration or repair | EXPEDITE - This scope is for the new oven rails with limited structural and electrical and fire sprinklers as required, this is for the oven pad area as installed with the… | – | |
| Plumbing | Pbi - add 2'' pipeline that runs parallel to existing 1'' pipeline | – | |
| Mechanical (HVAC) | Code modification - minimum heating capacity in building. Ref permit #bld2015-07441. | – | |
| Alteration or repair | Expedite-enclose existing, 8345 sqft truck loading area to keep out the elements. Existing fire sprinklers. Occ group b/s-1/f-1 construction type iiib/afes | – | |
| Plumbing | Ref bld2014-01204; gas line installed on main permit. Need an inspection for clearance. Gas line to run torches, belch fires and furnaces. | – | |
| Mechanical (HVAC) | Add automatic gate operators to existing manual east and west gates. | – | |
| Other | Deferred rack system - ref bld2014-01204 (see case notes) | – | |
| Fire systems | Pbi - fire panel w/ dialer for montoring fire sprinkler water flow and tamper. Ref bld2014-01204. Cut sheets only no plans required. | – | |
| Sign | Install three sets of non-illuminated reverse pan channel letters and painted logo to three elevations. To the east elevation "metso" with logo 73 sf and to the north and west… | – | |
| Fire systems | Deferred fire sprinklers, fees paid under main permit #bld2014-01204. Class d oven fire protection not included, separate permit req. | – | |
| Grading | At risk grading permit for metso copperstate,inc. Copy of dust control permit #e141087 and noi azcon-80504. No plans required for at risk grading work. | – | |
| Other | Deferred pre-engineered metal bldg frame. Reference main permit bld2014-01204: new light industrial office/warehouse building to include size & building improvements for… | – | |
| Fire systems | New 45,209 s.f. Light industrial office/warehouse building with includes 8345 s.f. Of f-1 under canopy and 20,916 s.f. F-1 fully enclosed (29,261 total f-1); 7,363 s.f. S-1, &… | – |
Mesa Development Services last updated its data Oct 1, 2026. We checked it 2026-10-02 00:41 UTC. Official data.