Alteration or repair at 428 E Main St
Mesa Development Services permit PMT24-19488, opened Nov 6, 2024 for 428 E Main St: alteration or repair. This project will be comprised of: changes on the existing monopole: · **paint to match or use 3m tape to conceal and meet at&t standards** · **cold swap due to mount swap** · remove all antennas · remove all rrhs · remove all nokia equipment · install (1) site pro 1 rmvd10-npnh dual level t-arm. Cut down the face horizontal length to 6.0 FT as needed to fit. (1) Per sector for a total of (3). · Install (2) 10’ long pipe 2.0 std per sector for proposed antennas for a total of (6). · Install (2) 10’ long pipe 2.0 std per sector for proposed radios for a total of (6). · Install (1) 8’ long corner tieback pipe 2.5 std per sector for a total of (3). · Install (3) ffvv-65b-r2-hg antennas a1/b1/c1. · Install (3) ffvv-65b-r2-hg antennas a2/b2/c2. · Install (3) air6419 b77d a7/b7/c7 (stacked above 6' antennas). · Install (3) air6419 b77g a8/b8/c8 (stacked above 6' antennas). · Install (3) 4490 b5/b12's radios on sxk1255394/2 b2b's to be shared w/ (3) 4415 b30's for a1/b1/c1 (N) 10' pipes on t-arm. · Install (3) 4890 b25/b66 on sxk1255394/2 b2b's to be shared w/ (3) 4478 b14's for a3/b3/c3 (N) 10' pipes on on sector on t-arm. · Install (1) pwrt-606 dc trunks · install (1) dc9-48-60-24-8c-ev squid · retain (1) 18 pair fiber and (1) 24 pair fiber · retain (1) dc6-48-60-18-8c squid and (1) dc9-48-60-24-8c-ev squid · retain (4) pwrt-608 dc trunks · retain (1) pwrt-606 dc trunks changes in the existing at&t equipment enclosure area: · remove all (E) radio cards · install (1) xmu, (2) 6651, (1) 6601 & (1) 6610 in cabinet dc power plan review: · retain existing emerson std -48vdc outdoor netsure 512 system with (11) rectifiers · install (1) vertiv r48-2000e3 rectifiers · install (1) vertiv std 48v to 58vdc outdoor conv system - 26 breakers (neq.57288) · install (9) 58v converters · install (1) commscope 48v/24v dc conv (ps-conv-48-24 · install (3) 50amp breakers for 4490 b5/b12 radios · install (3) 25amp breakers for 4415 b30 radios · install (6) 50amp breakers for air6419's radios · install (3) 50amp breakers for 4890 b25/b66 radios · install (3) 25amp breakers for 4478 b14 radios · connect 4478 b14 and 4415 b30 with #6 trunks and #10 jumpers to avoid converters battery check: · retain (32) 190 batteries
- Permit number
- PMT24-19488
- Opened
- Type of work
- Alteration or repair
- Status
- Issued
- Reported cost
- Not listed
- ZIP code
- 85203 (from the permit's location)
- City's category
- Macro Cell Site, Commercial Permit
- City's status
- C of C Issued
- Source
- Mesa Development Services permit data (this record)
Type of work and status are our standard labels, so permits compare across cities. The city's own wording is shown above. Costs under $100 are shown as not listed, because filers often enter $0 or $1 when no cost is required.
Mesa Development Services last updated its data Oct 1, 2026. We checked it 2026-10-02 09:00 UTC. Official data.