This report identifies permits and documentation required to obtain a permit for removal or restoration of
Alteration or repair at 11014 E Decatur St, Mesa
Mesa Development Services permit PMT25-16056: opened Sep 8, 2025 for alteration or repair work at 11014 E Decatur St. This report identifies permits and documentation required to obtain a permit for removal or restoration of the building to a safe condition. This report is not an appraisal for financial claims. The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. DATE: 7/1/2025 ADDRESS: 11014 E DECATUR ST MESA DAMAGE CAUSED BY: Fire INSPECTED BY: Richard Lemcke The inspection of the site identified the following: Please note that before a damage permit is issued an estimate showing the Company doing the work, the subject address, scope of work, materials, and labor from either the contractor or the insurance company will be required. A written scope of work is required to approximate the cost of the permit, verbal estimations shall not be used. This structure is to be restored like for like in compliance with 2017 NEC, 2018 IRC/IBC requirements. Any alterations or changes will require submitting plans before any restoration can begin. During the damage inspection the following was observed: Structural members may have been damaged by and will need an engineers observation letter. Electrical sustained minor damage. Any exposed wires that are not code compliant/damaged/or create life safety must comply with 2018 IRC/2017NEC. Mechanical equipment/ducts sustained minor damage. Will need to clean/repair ductwork Minor damage to plumbing, some pipes will need to be replaced or repaired. Note: Any structural members charred to a depth of 1/8" or greater are to be replaced. All plumbing, electrical and mechanical systems damaged by heat are to be replaced. A. Building is: Residential B. Building permits and inspections are required for the following phase(s) of construction: 1. Structural Yes 2 Electrical Yes 3. Mechanical Yes 4. Plumbing Yes 5. Construction Plans Required No Electrical service can be restored under the following conditions: Restoring power for landscaping, pool and restoration repairs. Ok to release electric. Contractor responsible for lock out tag out and any damages resulting from the power being turned on. Failure to obtain a full permit in 30 days may result in the removal of power. Natural gas service can only be restored after a gas test has been approved by the building inspectorReconstruction after Fire in Master Bathroom.
- Permit number
- PMT25-16056
- Opened
- Type of work
- Alteration or repair
- Status
- Issued
- Reported cost
- Not listed
- ZIP code
- 85207 (from the permit's location)
- City's category
- Renovations/Remodels, Residential Permit
- City's status
- C of C Issued
- Source
- Mesa Development Services permit data (this record)
Type of work and status are our own standard labels, so permits compare across cities. The city's wording is in the "City's category" and "City's status" rows. We show costs under $100 as not listed, because filers often enter $0 or $1 when the city doesn't require a cost.
All permits at 11014 E Decatur St, and what's permitted nearby
Mesa Development Services updated its data Oct 4, 2026. We checked it Oct 5, 12:01 UTC. Official data.
For agents and scripts: This page as Markdown ยท JSON