Nearby Permits

The building inspector may require portions of the building or other debris to be removed to allow evaluation

Alteration or repair at 3153 S Vineyard, Mesa

Mesa Development Services permit PMT25-19209: opened Oct 21, 2025 for alteration or repair work at 3153 S Vineyard. The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. DATE: 9/24/2025 ADDRESS: 3153 S VINEYARD MESA DAMAGE CAUSED BY: Fire INSPECTED BY: Richard Lemcke The inspection of the site identified the following: Please note that before a damage permit is issued an estimate showing the Company doing the work, the subject address, scope of work, materials, and labor from either the contractor or the insurance company will be required. A written scope of work is required to approximate the cost of the permit, verbal estimations shall not be used. This structure is to be restored like for like in compliance with 2017 NEC, 2018 IRC/IBC requirements. Any alterations or changes will require submitting plans before any restoration can begin. During the damage inspection the following was observed: Structural members were damaged by and will need stamped engineering. Electrical sustained damage to several home runs, panel may not need to be replaced unless it can?t accommodate the requirements needed to comply with 2018 IRC/IBC and/or 2017 NEC. All damaged wires must be replaced per 2017 NEC/2018 IRC. Mechanical equipment was damaged, and all mechanical components will need replacing. Minor damage to plumbing, some pipes will need to be replaced or repaired. Note: Any structural members charred to a depth of 1/8" or greater are to be replaced. All plumbing, electrical and mechanical systems damaged by heat are to be replaced. A. Building is: Residential B. Building permits and inspections are required for the following phase(s) of construction: 1. Structural Yes 2 Electrical Yes 3. Mechanical Yes 4. Plumbing Yes 5. Construction Plans Required No Electrical service can be restored under the following conditions: Temp electric can be issued during construction, however the City of Mesa reserves the right to disconnect power if time between inspections go beyond 90 days or work is being done without a permit. Mesa reserves the right to disconnect power if inspections process is not followed or the property is being occupied without obtaining a C of O/ C of C.

Permit number
PMT25-19209
Opened
Type of work
Alteration or repair
Status
Issued
Reported cost
Not listed
ZIP code
85210 (from the permit's location)
City's category
Renovations/Remodels, Residential Permit
City's status
C of C Issued
Source
Mesa Development Services permit data (this record)

Type of work and status are our own standard labels, so permits compare across cities. The city's wording is in the "City's category" and "City's status" rows. We show costs under $100 as not listed, because filers often enter $0 or $1 when the city doesn't require a cost.

All permits at 3153 S Vineyard, and what's permitted nearby

Mesa Development Services updated its data Oct 4, 2026. We checked it Oct 5, 18:26 UTC. See the city's official records.

For agents and scripts: This page as Markdown ยท JSON