New 200A Service Installation Panel Installation: Install one (1) new Leviton 150-200-Amp Load Center with a

Electrical at 4198 Nevis St, Boulder

Boulder Planning and Development Services permit ELE2026-00960: issued Sep 4, 2026 for electrical work at 4198 Nevis St. New 200A Service Installation Panel Installation: Install one (1) new Leviton 150-200-Amp Load Center with a main service disconnect. Ensure the panel is plumb, level, and securely fastened. https://leviton.com/products/residential/load-centers Service Conductor Installation: Connect service entrance conductors from the utility connection point to the line side of the new meter socket. Grounding Electrode System (GES): Install new GES that meets or exceeds NEC Article 250 requirements as needed. Drive new 8-foot copper-clad ground rods, spaced a minimum of 6 feet apart as needed. Install a continuous #4 AWG bare copper Grounding Electrode Conductor (GEC) from the panel's neutral/ground bus to both ground rods using approved acorn clamps as needed. Install a new Intersystem Bonding Bridge and connect it to the GEC for the bonding of telephone, cable, and satellite systems as needed. Whole-Home Surge Protection: Install one (1) new Leviton Type 1 or Type 2 Whole-Home Surge Protective Device (SPD) inside the load center. Connect the SPD to a dedicated 2-pole circuit breaker, positioned as close to the main breaker as physically possible to ensure maximum effectiveness, per manufacturer and NEC best practices. Circuit Reconnection & Breaker Installation Circuit Re-routing: Extend existing branch circuit wiring as necessary to neatly enter the new load center. All connections will be made within approved junction boxes if required. Breaker Installation: Install new Leviton circuit breakers for all branch circuits, sized appropriately for the connected wire gauge. Breakers shall include modern safety features as required by the current NEC: Dual-Function AFCI/GFCI Breakers: For all circuits requiring both Arc-Fault and Ground-Fault protection, including kitchens, bathrooms, laundry rooms, garages, and outdoor outlets. Arc-Fault (AFCI) Breakers: For all circuits requiring Arc-Fault protection, including bedrooms, living rooms, hallways, dining rooms, and other general living spaces. Standard Breakers: For circuits that do not require AFCI/GFCI protection, such as a dedicated furnace or fire alarm circuit. Electrical Wiring.

Permit number
ELE2026-00960
Issued
Type of work
Electrical
Status
Issued
Reported cost
$12,000
ZIP code
80301
City's category
Electrical Permit, Electrical Permit
City's status
Issued
Source
Boulder Planning and Development Services permit data (this record)

Type of work and status are our own standard labels, so permits compare across cities. The city's wording is in the "City's category" and "City's status" rows. We show costs under $100 as not listed, because filers often enter $0 or $1 when the city doesn't require a cost.

All permits at 4198 Nevis St, and what's permitted nearby

Boulder Planning and Development Services updated its data Oct 7, 2026. We checked it Oct 8, 00:54 UTC. See the city's official records.

For agents and scripts: This page as Markdown · JSON