Section A&B: Third party to modify select MEP items > Remove existing roof > Check roof deck joints to see if
Roofing at 600 E Hurst Blvd, Fort Worth
Fort Worth Development Services Department permit PB25-15333: opened Nov 3, 2025 for roofing work at 600 E Hurst Blvd. Section A&B: Third party to modify select MEP items > Remove existing roof > Check roof deck joints to see if sealed or unsealed. If unsealed and greater than 1" in width, cover joints with strip of vapor barrirer membrane > Adhere 1/8" per foot fully tapered insulation to the concrete roof deck (start with A panel at 1.0" thickness) > Adhere 1/4" per foot polyiso crickets where applicable > Adhere DensDeck Prime StormX board to insulation > Adhere Johns Manville 115-mil Fleeceback TPO to coverboard Section C&D: Third party to install interior protection > Remove existing roof > Loose lay 1/2" DEXcell FA roof board on steel deck > Self-adhere JM Vapor Barrier SA to gypsum board > loose lay one (1) layer of 3.5" polyiso insulation > loose lay 1/2" per foot polyiso crickets where applicable > Mechanically gang fasten 5/8" DEXCell FA VSH board through lower layers to steel deck > Adhere Johns Manville 135-mil Fleeceback TPO to coverboard Section E: Third party to install interior protection > third party to modify select MEP items > Remove existing roof > Loose lay 1/2" DEXcell FA roof board on steel deck > Self-adhere JM Vapor Barrier SA to gypsum board > loose lay 1/8" per foot fully tapered insulation on vapor barrier (start with C panel at 2.0" thickness) > Loose lay 1/4" per foot polyiso crickets where applicable > Mechanically gang fasten 5/8" DEXCell FA VSH board through lower layers to steel deck > Adhere Johns Manville 135-mil Fleeceback TPO to coverboard Air Traffic Control Tower: Remove existing roof > Loose lay 1/2" DEXcell FA roof board on steel deck > Self-adhere JM Vapor Barrier SA to gypsum board > loose lay two (2) layers of 2.2" polyiso insulation > Mechanically gang fasten 5/8" DEXCell FA VSH board through lower layers to steel deck > Adhere Johns Manville 135-mil Fleeceback TPO to coverboard.
- Permit number
- PB25-15333
- Opened
- Type of work
- Roofing
- Status
- Finished
- Reported cost
- $1,536,247
- ZIP code
- 76053
- City's category
- Commercial Building Permit, Remodel
- City's status
- Finaled
- Source
- Fort Worth Development Services Department permit data (this record)
Type of work and status are our own standard labels, so permits compare across cities. The city's wording is in the "City's category" and "City's status" rows. We show costs under $100 as not listed, because filers often enter $0 or $1 when the city doesn't require a cost.
All permits at 600 E Hurst Blvd, and what's permitted nearby
Fort Worth Development Services Department updated its data Oct 10, 2026. We checked it Oct 10, 07:17 UTC. See the city's official records (City of Fort Worth, CC BY 4.0).
For agents and scripts: This page as Markdown · JSON