Code mod #2, ref
Addition at 11202 E Germann Rd, Mesa
Mesa Development Services permit BLD2010-02398: opened May 27, 2010 for addition work at 11202 E Germann Rd. Code mod #2, ref. BLD2010-02323 - TRW AM&M A15P.O2 - APPROVED - Code Modification is to use "INTERCEPTOR-QR" indoor explosion venting system to comply with the explosion control provisions of IBC Section and Table 414.5.1. The CV Technology "INTERCEPTOR-QR" indoor explosion venting system is FM approved in sizes 8 through 32. SMS tested the propellant load chamber and a size 16 "INTERCEPTOR-QR" assembly that will be installed on the final assembly line in Area P-2, the assembly passed. See the test set up and results in SMS report SMS-2175-R1. This code modification and SMS report SMS-2175R1 are attached under documents tag.
- Permit number
- BLD2010-02398
- Opened
- Type of work
- Addition
- Status
- Finished
- Reported cost
- Not listed
- ZIP code
- 85212 (from the permit's location)
- City's category
- Com (OTH) -- Remodeling with Addition
- City's status
- Finaled
- Source
- Mesa Development Services permit data (this record)
Type of work and status are our own standard labels, so permits compare across cities. The city's wording is in the "City's category" and "City's status" rows. We show costs under $100 as not listed, because filers often enter $0 or $1 when the city doesn't require a cost.
All permits at 11202 E Germann Rd, and what's permitted nearby
Mesa Development Services updated its data Oct 7, 2026. We checked it Oct 8, 09:16 UTC. See the city's official records (City of Mesa).
For agents and scripts: This page as Markdown · JSON